RadiMation Error: 536881993: Difference between revisions
Jump to navigation
Jump to search
(New page: = The selected frequency step is not supported in emission tests = RadiMation has detected that unsupported type of frequency step is used in an emission test. The multiband emission ...) |
No edit summary |
||
Line 6: | Line 6: | ||
== Solution == | == Solution == | ||
* Change the selected step frequency type to a linear step frequency or a logarithmic step frequency. | * Change the selected step frequency type to a linear step frequency or a logarithmic step frequency. | ||
* If a spectrum | * If a spectrum analyser is used, ensure that a linear step frequency is used. | ||
[[Category:RadiMation Error]] | [[Category:RadiMation Error]] | ||
[[Category:RadiMation]] | [[Category:RadiMation]] |
Latest revision as of 08:57, 3 January 2020
The selected frequency step is not supported in emission tests[edit]
RadiMation has detected that unsupported type of frequency step is used in an emission test. The multiband emission tests, only support a linear step frequency and a logarithmic step frequency. Other step types that are available in multiband immunity tests, cannot be used in emission tests. The logarithmic step frequency is also only available if a (scanning) receiver is used. The logarithmic step frequency cannot be used in combination with a spectrum analyser.
Solution[edit]
- Change the selected step frequency type to a linear step frequency or a logarithmic step frequency.
- If a spectrum analyser is used, ensure that a linear step frequency is used.