RadiMation Error: 536881993

From RadiWiki
Revision as of 08:57, 3 January 2020 by Madero17 (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

The selected frequency step is not supported in emission tests[edit]

RadiMation has detected that unsupported type of frequency step is used in an emission test. The multiband emission tests, only support a linear step frequency and a logarithmic step frequency. Other step types that are available in multiband immunity tests, cannot be used in emission tests. The logarithmic step frequency is also only available if a (scanning) receiver is used. The logarithmic step frequency cannot be used in combination with a spectrum analyser.

Solution[edit]

  • Change the selected step frequency type to a linear step frequency or a logarithmic step frequency.
  • If a spectrum analyser is used, ensure that a linear step frequency is used.