== RadiMation version 2021.2.7 ==
 
== RadiMation version 2021.2.7 ==
 +
* #4246: Possibility to insert note in "read only" protected TSF before mesurement starts
 +
* #10935: CI manual mode. Make sure to set the settings of the signal generator when modulation is switched of and on so that this setting is imediatly applied
 +
* #11373: DARE!! Development RadiSense IV: Device returned Error code : 4.
 +
* #11739: Add option in R&S ESW driver to active low noise amplifier (for lower noise floor)
 
* #11846: Measured differences between RadiMation and PMM software when Testing CE/RE
 
* #11846: Measured differences between RadiMation and PMM software when Testing CE/RE
 
* #12078: Absorbing clamp Maturo FCU: Function not implemented error
 
* #12078: Absorbing clamp Maturo FCU: Function not implemented error
 
* #12087: Opening test data older than 2021.2.1 results in missing distance data
 
* #12087: Opening test data older than 2021.2.1 results in missing distance data
 
* #12088: ErrorReport: "RI with rot pos, 1 step, 120 degrees".
 
* #12088: ErrorReport: "RI with rot pos, 1 step, 120 degrees".
 +
* #12091: Build RadiMation 2021.2.7
 +
* #12144: Device driver configuration dialog cannot be shown, due to problem of loading GenericTabbedDialog
 +
* #12147: How to disable the power delivery test, to prevent that generated frequencies are really in order
 +
* #12165: Start Frequency is too low for the selected equipment
 +
* #12211: Ability to use an automatic calkit for the R&S ZNB VNA calibration
 +
* #12217: Agilent technologies U2004A driver problem: Insufficient location information
 +
* #12219: Rohde & Schwarz NRP-Z91: Impossible to get description string for this Error! Probably an unknown RadiMation Error. Code:  805313470 (0x30001BBE)
 +
* #12239: Driver: MTS Systemtechnik KRE-4000
 +
* #12291: Question: Forward power amplifier protection file is not found
 +
* #12293: Error message: There is no average probe selected
 +
* #12295: Incorrect RBW of 1 MHz with QP detector in range 1GHz-6GHz

Latest revision as of 13:15, 20 January 2022

RadiMation version 2021.2.7

  • #4246: Possibility to insert note in "read only" protected TSF before mesurement starts
  • #10935: CI manual mode. Make sure to set the settings of the signal generator when modulation is switched of and on so that this setting is imediatly applied
  • #11373: DARE!! Development RadiSense IV: Device returned Error code : 4.
  • #11739: Add option in R&S ESW driver to active low noise amplifier (for lower noise floor)
  • #11846: Measured differences between RadiMation and PMM software when Testing CE/RE
  • #12078: Absorbing clamp Maturo FCU: Function not implemented error
  • #12087: Opening test data older than 2021.2.1 results in missing distance data
  • #12088: ErrorReport: "RI with rot pos, 1 step, 120 degrees".
  • #12091: Build RadiMation 2021.2.7
  • #12144: Device driver configuration dialog cannot be shown, due to problem of loading GenericTabbedDialog
  • #12147: How to disable the power delivery test, to prevent that generated frequencies are really in order
  • #12165: Start Frequency is too low for the selected equipment
  • #12211: Ability to use an automatic calkit for the R&S ZNB VNA calibration
  • #12217: Agilent technologies U2004A driver problem: Insufficient location information
  • #12219: Rohde & Schwarz NRP-Z91: Impossible to get description string for this Error! Probably an unknown RadiMation Error. Code: 805313470 (0x30001BBE)
  • #12239: Driver: MTS Systemtechnik KRE-4000
  • #12291: Question: Forward power amplifier protection file is not found
  • #12293: Error message: There is no average probe selected
  • #12295: Incorrect RBW of 1 MHz with QP detector in range 1GHz-6GHz