Release Notes/Solved items Version 2023.2.7
Jump to navigation
Jump to search
RadiMation version 2023.2.7[edit]
- #13571: Driver: Keithley DMM7510
- #13771: Driver: Agilent DSO9104A
- #13865: Prevent DMM6500 from showing error -102 during measurement
- #13911: TDEMI ULTRA changed RBW from 1 kHz to 120 kHz
- #13911: TDEMI add MIL suffix to command when selecting MIL and DO RBW values
- #14605: Clearing the time-out error resulting by an EP600 results in an infinite retry loop
- #14385: Driver: Ceyear Technologies 87235H powermeter
- #14394: R&S EPL correctly selects 9 kHz RBW without an error
- #14396: R&S EPL correctly selects 9 kHz RBW without an error
- #14426: N9010 Prevent settings conflict regarding the step size from occuring after initializing the device
- #14488: Rigol DSA832 Trigggers a new video averaging measurement when takesweep is called
- #14517: Export the test site, polarisation and antenna distance correctly in the multi band export function
- #14534: 20 dB difference in conducted emission measurement
- #14578: Rigol DSA832 ensure that the AV measurements are running for the expected duration
- #14598: Extend the keywords supported by the configurable EUT controller
- #14618: R&S ESR 3 add option B29 for measuring under 9 kHz
- #14622: Prevent Error -102 on Keithley DMM 6500 with scanner card 2000
- #14628: Pulse mode setting of RSS3018U is enabled to allow pulse measurement mode
- #14631: Maturo NCD Tried to often to go to correct angle and does not start tower movement
- #14637: FSV: Incorrect average value at final measurement
- #14646: CI calibration with Rigol RSA3030N
- #14647: VCS 500 detect coupling device
- #14656: Add manual controlled Applied Systems Engineering -CW amplifiers.
- #14659: Driver: ETS-Lindgren 8000-044 amplifier
- #14662: Changed behavior regarding requesting DeviceSpecificSettings resulting in errors when connecting to VI power meters
- #14667: FSV40 Error 'BAND:AUTO OFF' at RE final measurement
- #14688: Observation time set during the initialisation of the RSS3018U will be at least the minimum observation time
- #14675: Rohde & Schwarz ESR Allow start frequency of 10 Hz with option B29
- #14680: Agilent 33521A returns illigal parameter value when using pulse function
- #14680: Agilent 33521A apply external PM modulation using the GATE input
- #14681: MCU Turntable raises error after retrieving current position
- #14684: Export of CAL file in a multiband test correctly exports the polarisation, test site name and antenna distance
- #14685: PMM EP600 probe should raise an error when the battery is empty
- #14691: RadiSense Ultra needs more time to startup
- #14692: Allow selection of range of RadiSense Ultra
- #14717: User calibration upload is removed for the Raditeq RadiSense RSS3018U
- #14724: Maturo MCU turntable does not move when requested
- #14732: Improved retrieval of the measurement traces from the PMM 9010F
- #14734: Some configurable EUT controller keywords are not replaced
- #14751: Driver: Schwarzbeck – VULB9164
- #14752: Driver: Bonn – BLMA 1040-30/20D
- #14753: Driver: keysight U2061XA power meter
- #14755: RadiMation hangs while opening RPR4006R driver
- #14757: RadiPower gives different measurement results at the same input level at the same setup when connected to different PC's
- #14771: Substitution for a value which cannot be converted to a logarithmic value should return a very low value
- #14774: Fix old 2020.0.7 TSF cannot be opened in 2023.2
- #14787: Warning in Device Mode with Holday HI-6005 EM-field probe
- #14788: Issue should be resolved by updating the device driver system
- #14792: FC04 Antenna Tower ignore height setting can be changed
- #14793: Fix old 2020.0.7 TSF cannot be opened in 2023.2
- #14796: FC04 Antenna Tower -100 command error
- #14800: Use correct start and stop frequency for the Anritsu 68369B
- #14804: Apply the angle offset set in the FC06.1 controller
- #14808: RS ESRP Limit start frequency by value returned of "FREQ:STAR? MIN"
- #14820: Frequency is now always forwarded to the RadiSense RSS3018U
- #14825: TDEMI correctly limits the RBW when used in analyser mode
- #14827: Improved the retry in check device of radisense driver
- #14834: TDEMI correctly limits the RBW when used in receiver mode
- #14836: Only use CISPR RBW Bandwidths when using the TDEMI in receiver mode as power meter
- #14837: Only include a configurable communication delay in the FC06.1 antenna tower controller
- #14839: ||AD GRAPH X|| keywords do not seem to work when generating reports
- #14842: FC06.1 Turn table, Correctly load/save the wait time setting
- #14845: FC06.1 Correctly handle error code when wrong device is configured in settings
- #14847: Climate chamber, fix events for buttons on information form
- #14849: Correctly set the default value for EUT information item lists
- #14852: Improve the speed of the FC06.1 turn table
- #14858: Dynamically set the filter bandwith based on the measurement frequency
- #14877: FCU clampmover requests positions again as integer values
- #14895: Improve the speed of the FC06.1 turn table
- #14903: Leading and trailing whitespace is stripped from name of information item in configurable switch matrix keywords
- #14908: Rohde & Schwarz ESU / ESW now also uses the LNA option in auto mode
- #14920: Add driver TESEQ CVP 2200A
- #14926: Unexpected values from EP600 field probe
- #14497: Driver: Keithley DAQ6510