Release Notes/Solved items Version 2024.2.6

From RadiWiki
Jump to navigation Jump to search

RadiMation version 2024.2.6[edit]

  • #6508: USB controlled RadiCentre does not require National Instruments VISA anymore
  • #14984: R&S ESR3 Fix an error -222 when applying the RBW after the center frequency has changed
  • #15624: TDEMI unexpected differences in measurement results when the pre-selector has been activated and a reduced span is being measured
  • #15708: Extended the mk motion driver to support retrieval of values from OCR
  • #15746: Driver Siglent spectrum analyzer model SSA5085A
  • #15761: Extended the mk motion driver to support retrieval of values from OCR
  • #15848: R&S OSP switching commands are retransmitted when an error has happened before
  • #15907: fixes related to double inclusion of monitorig input graph lines
  • #15928: MSO 3000 series fixes related to division scaling
  • #15955: Device driver to check if the serial number of the tested EUT is the same as the serial number in the EUT file
  • #15963: dBm is shown along the Y-axis for a radiated emission test
  • #15968: Fix AC DC coupling selection for the R&S ESCI
  • #15974: R&S SMCV100B changed default port and IP adress in driver settings
  • #15975: Fix setting the receiver measurement time for the R&S FPL
  • #15979: Fix AC DC coupling selection for the tektronix TDS scopes
  • #15980: unexpected results performing the amplifier harmonics test
  • #15985: Allow lower signal generator levels in harmonics eut test
  • #15986: Allow lower signal generator levels in network analyser test
  • #15989: Network analyser test stimilus limit removed of -20 dBm
  • #15991: Performing a final measurement with multiple detectors during a GTEM test is now working correctly
  • #16000: IFI SCCX750: Fixes related to initialization behavior
  • #16001: RSS2000 will not send MEASMODE with probe versions older than 2.0.6
  • #16004: FSW43 Do not use AUTO sweep time while in zero span
  • #16008: Improvements to rounding of floating points
  • #16009: Switching relay of R&S OSP, module OSP-B136 is now supported
  • #16018: EUT Serial number checker, show serial numbers in correct order when they do not match
  • #16020: Make RadiSense IDN checks more strict
  • #16023: Driver Keysight AP5000 series
  • #16027: Teseq NSG 4070 can also be controlled using the TCP/IP connection (without an installed VISA library)
  • #16040: R&S ESI Data out of range;SCAN1:BAND:RES
  • #16058: Serial number checker is now able to ignore communication errors
  • #16064: fixed the error message 'clsCommandSendSwitchMatrixEvent is not registered'
  • #16067: use longer timeout for em test CWS500N1.3 and firmware version >= v9
  • #16070: Driver: Raditeq RGN2001B
  • #16075: fixed the error message 'clsCommandStopRotPositioner is not registered'
  • #16080: NX7 unexpected syncronisation errors
  • #16082: em test CWS500N1.3 power meter driver, use longer wait times for firmware version 9 and higher
  • #16084: NX7 unexpected syncronisation errors
  • #16085: Fixes related to resizing of graphs in RI multiband test
  • #16086: Fix Keysight 34450A and 34405A: No measurements are performed by the device
  • #16095: Fix device driver system warning ranges
  • #16106: Fix label for the EFT multiband test
  • #16171: Verify that the correction file check uses the start frequency of the configured band, instead of the first frequency of the frequency list.