Release Notes/Solved items Version 5.5

From RadiWiki
Jump to: navigation, search

RadiMation version 5.5.13

  • #3536: Crash when a graph is shown
  • #3550: Configuration directory path uses a limited path length

RadiMation version 5.5.12

  • #3506: 5.1 dB limitation does not work correctly with ci fixed current test.

RadiMation version 5.5.11

  • #3498: Merge function does not support the G-tem test.

RadiMation version 5.5.10

  • #2626: Capl interface is lacking the turn table and the antenna polarisation

RadiMation version 5.5.9

  • #3393: Radimation Multiband Anechoic Chamber dBuV - dBm projection is incorrect

RadiMation version 5.5.8

  • #3481: Import rsus substitution file is incorrect
  • #3448: Conducted Immunity Fixed Current with activated performance threshold is crashing

RadiMation version 5.5.7

  • #3467: R&S ZVK results in zero's-measurement in S Parameter calibration
  • #3402: ESD Pos Horizontal is always deselected in the tsf file.
  • #3401: Agilent PSA 4440 shows error message PreselConnFail
  • #3400: Test Date in the report generator is showing the year 1899
  • #3399: HP8657 signal generator driver does not support 400 Hz AM.
  • #3392: clean install sets the configuration directory incorrectly to Radimationconfdvdr
  • #3391: Clean install crashes when opening device driver configuration window
  • #3329: Customization of the Graph lines crashes RadiMation
  • #3301: ESU driver input 2 is not selecting input 2
  • #3296: With R&S ESVS10 it is not possible to set a measure step of 1MHz: only up to 999kHz
  • #3286: Change D.A.R.E!! Development to D.A.R.E!! instruments
  • #3254: ESVS10 deinitialization at the end of RE test is very long.
  • #3249: 40 dB switched HP 33120 Signal generator can generate overshoots
  • #3248: Selecting square wave AM modulation does not change the waveform on the Agilent 83640B, and it doesn't raise an error
  • #3086: ESU-40 as a powermeter device driver
  • #2822: RadiMate4 shows an inrelevant peak at the first measurement point
  • #2716: Calibration file is not being saved if the selection of the filename to save the file to is going wrong
  • #2643: fsp7 is giving unknow command -100 Trac? Trace1
  • #2588: Error when a detector measure time larger than two seconds is set for the R&S ESI

RadiMation version 5.5.6

  • #2959: inverted gain on an AR amplifier should configurable on the configuration screen.
  • #3226: graphs in automatically created report missing.
  • #3374: Driver for ESU-8 uses always input 1.
  • #3385: AR Amplifiers driver advanced P1/p0 set does not support clearing of the error status.
  • #3387: Driver: HP 8592B as a power meter.
  • #3389: EUT information can not be edited any more.

RadiMation version 5.5.5

  • #3358: Error message while opening ESD TSF file
  • #2970: RadiMation shutdown crash

RadiMation version 5.5.4

  • #3042: When interrupting a test by clicking on the “cancel” button, the amps are still in operate and the signal generator output is also still “ON”.
  • #3224: Metrahit AD convertor test is crashing.
  • #3322: Changing parameters modulation in Multi band test resuls in modulation being turned off instead of applied.
  • #3366: Combobox is still in memory when closing the multiband RE test.
  • #3369: During Ri calibration no can not reach the tolerance message is displayed.
  • #3370: Test leveling should always be overtesting.

RadiMation version 5.5.3

  • #3368: Crash when pressing markers in the graph customization window in a new installation.
  • #3365: SMB 100A is going to 0 dBm all the time
  • #3358: Error message while opening ESD TSF file
  • #3355: Driver: AR 2500A250A
  • #3350: Engineer log in window is not unloaded correctly when false password is given.
  • #3348: impossible to work with surge test, tabs keep on changing
  • #3346: Driver: BLWA 0810-100
  • #3345: Driver: Agilent PSA 4440
  • #3340: Rs-232 support for fluke 45
  • #3330: SMB 100A starts at 0 dBm
  • #3328: Changes to the description of the limit line doesn't mark the file as changed
  • #3327: PMM 9010 is giving error during the Init
  • #3315: 180 degrees angle is missing at the Surge test field
  • #3314: "STEP FREQUENCY" in generated report is empty
  • #3311: In Limit Line definition, button Graph/Customize is present but not working
  • #3287: changing the test site in a save tsf is not detected correctly
  • #3276: Driver: Current Clamps for installation
  • #3275: Time formating is not according to the pc settings
  • #3255: Even if the option is disabled, Zoom-in is performed for RE Multiband
  • #3250: Driver for amplifier Milmega AS0104-100/100
  • #3238: Unexpected switching of tabs
  • #3210: Ramp is not correct for certain frequencies, it either does not ramp or ramps first down and then up again
  • #3153: Improve selection of bands to be more 'the Windows way of doing it'
  • #3140: Dip in stress test while doing imm. test
  • #2997: Bad AM peak conservation for BCI closed loop limited to 4x cal power.
  • #2876: Surge test does not allow 180 degrees test
  • #2797: Wrong limitation of forward power when using AM modulation

RadiMation version 5.5.2

  • #3335: Driver Hameg HM 8150
  • #3332: calculated field strength on CAN-Bus
  • #3325: Add a limit line in a MB TSF file takes 15 seconds
  • #3321: pulsed report generation is not inserting several key words.
  • #3305: SM300 is crashing when pressing sys in the manual mode window of RadiMation.
  • #3302: Issues with R&S SM300 signal generator and driver.

RadiMation version 5.5.1

  • #3309: Every time the menu Configuration/Configuration is open, the information of the report format (doc, xls) previously defined is not retained and is set again on excel report
  • #3306: ESU 8 lan driver does not exist.
  • #3298: R & S SM300 driver does not return the correct error message
  • #3292: FM 5004 range selection window is always 1 range too high
  • #3291: PMM 8053A is not detected on the comport
  • #3290: Improved english translation in the Uniform Field Area Calculation
  • #3288: RadiPower driver for usb is "slow"
  • #3268: Opening test results takes 20 seconds
  • #3253: Gigatronics 8542C driver is not working correctly during the test while the check is performed correctly
  • #3218: AD convertor Canalyser is crashing with Canalyser V.7.0.75

RadiMation version 5.5.0

  • #3274: Administrator is the only person who can change the configuration.
  • #3273: Note window is not resizable
  • #3259: Enable the 'Knowledge' button on the device driver settings window by default
  • #3258: Not available field probes and powermeters cannot be disabled under the input configuration
  • #3256: Upgrade wxWidgets library to 2.8.9
  • #3252: Start frequency extention of the Milmega AS0104 from 1 GHz to 800 MHz.
  • #3247: Using pulse modulation of the R&S SMR raises a GPIB timeout error
  • #3244: SMR is giving GPIB time out when setting the AM modulation parameters
  • #3243: Gtem measurement has jump at 500 Mhz with 10 Meter oats correlation
  • #3237: Driver: 75A400
  • #3234: Graph and time bar CI subst does not continue after the manual mode
  • #3233: Sorting and deleting tests is not working correctly for 5.4.9
  • #3229: 5.4.8 has screen update problems
  • #3227: NI 6009 is giving error message during the check of the device.
  • #3220: Scaling of the Tsf selection window
  • #3192: Improve the visibility of the Pause test
  • #3188: The advanced option window can not be scaled to the max of the window.
  • #3187: Driver Lecroy 534 AL
  • #2949: Screen shot RadiMation manual is outdated
  • #2942: Driver: couplers
  • #2899: Limitation of forward power during BCI Test
  • #2896: Driver: Bonn BAS 0240-2
  • #2282: Auto opdate the version in the manual