Talk:RadiMation Application Note 120

From RadiWiki
Jump to: navigation, search

Ticket

Also see: #9486.

Pictures

For the pictures of the schematic setup, see the powerpoint file in: [svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"

Pictures of calibration setup:

signal generator - connector - connector - analyser as powermeter

Picture of eut setup:

Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter

Required levels

BMW GS 95002-3

  • Signal generator level: minimum 0 dBm
  • Analyser: 120 kHz RBW
  • Frequency step: logarithmic
  • Frequency step width: max 500 kHz
  • Freq-range: 0.10 MHz - 1000 MHz


CISPR 25

  • Signal generator level: recommended: 0 dBm
  • Minimum number of points: 401 points
  • Frequency step: logarithmic


Review Status

JORO: Reviewed. Joro (talk) 22:12, 10 April 2019 (CEST)