User:Jewe: Difference between revisions
Jump to navigation
Jump to search
Line 36: | Line 36: | ||
==Normal operation mode== | ==Normal operation mode== | ||
{{note|All modulations needs to tested with a scope if the signal generator does not allow the settings to be read from the display.}} | |||
==Error operation mode== | ==Error operation mode== |
Revision as of 07:40, 31 August 2009
- make new getting started
Signal generator driver test
The following settings need to be tested:
Normal operation mode
- Amplitude
- Frequency
- AM, 80% 1 kHz
- FM
- PM 50% 1 KHz.
- AM external.
- FM external.
- PM external.
- Sine wave for amplitude modulation
- Square wave for amplitude modulation
Note: | All modulations needs to tested with a scope if the signal generator does not allow the settings to be read from the display. |
Error operation mode
- unplug the communication cable during testing
- Set the AM to out of boundary settings, for example 0% or 1 MHz, this is not supported by the machine.
- Set the FM to out of boundary settings, for example 1 Hz or 1 MHz, this is not supported by the machine.
- Set the PM to out of boundary settings, for example 0,1 Hz and 1%.
Note: | With all out of boundary settings an error must be generated. |
Spectrum analyser driver test
The following settings need to be tested:
Normal operation mode
Note: | All modulations needs to tested with a scope if the signal generator does not allow the settings to be read from the display. |