RadiMationInterface.can: Difference between revisions
Line 53: | Line 53: | ||
==Test_Modulation_Off== | ==Test_Modulation_Off== | ||
==Antenna_Movement_Started== | ==Antenna_Movement_Started== | ||
Starting of the movement of the antenna tower with the target position of the antenna tower. | |||
'''Parameter:''' position | |||
'''Unit parameter:''' Meter | |||
==Antenna_Movement_Stopped== | ==Antenna_Movement_Stopped== | ||
The stop position of the antenna tower. | |||
'''Parameter:''' position | |||
'''Unit parameter:''' Meter | |||
==Antenna_Movement_Percentage== | ==Antenna_Movement_Percentage== | ||
The current percentage of the antenna tower movement from the start position to the end position | |||
'''Parameter:''' percentage | |||
'''Unit parameter:''' % | |||
==Antenna_Movement_Changing_Polarisation== | ==Antenna_Movement_Changing_Polarisation== | ||
==TurnTable_Movement_Started== | ==TurnTable_Movement_Started== | ||
Starting of the movement of the turn table with the target position of the turn table. | |||
'''Parameter:''' position | |||
'''Unit parameter:''' Degrees | |||
==TurnTable_Movement_Stopped== | ==TurnTable_Movement_Stopped== | ||
The stop position of the turn table. | |||
'''Parameter:''' position | |||
'''Unit parameter:''' Degrees | |||
==TurnTable_Movement_Turning_Percentage== | ==TurnTable_Movement_Turning_Percentage== | ||
The current percentage of the turn table movement from the start position to the end position | |||
'''Parameter:''' percentage | |||
'''Unit parameter:''' % |
Revision as of 08:59, 28 October 2010
The RadiMationInterface.can is an interface between the RadiMation software and CANoe and CANalyser.
By inserting this file inside your CANoe/CANalyser project you are able to extract information from RadiMation using CANoe/CANalyser.
You can download the file here
Explanation of available events/functions[edit]
Test_Frequency[edit]
The current frequency of the test, in other words the frequency of the signal generator.
Parameter: mdFreqMHz
Unit parameter: MHz
Test_Carrier_Level[edit]
The carrier level of the signal generator
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Forward_Power[edit]
The measured value of the forward power.
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Reflected_Power[edit]
The measured value of the reflected power.
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Average_Field[edit]
The measured value of the average field.
Parameter: mdFieldVm
Unit parameter: V/m
Test_Calculated_Field[edit]
The calculated value of the field based on the calibration file.
Parameter: mdFieldVm
Unit parameter: V/m
Test_Measured_Current[edit]
Test_Sensor_Power[edit]
Test_Amplitude_Modulation_Internal[edit]
Test_Amplitude_Modulation_External[edit]
Test_Frequency_Modulation_Internal[edit]
Test_Frequency_Modulation_External[edit]
Test_Pulse_Modulation_Internal[edit]
Test_Pulse_Modulation_External[edit]
Test_Modulation_On[edit]
Test_Modulation_Off[edit]
Antenna_Movement_Started[edit]
Starting of the movement of the antenna tower with the target position of the antenna tower.
Parameter: position
Unit parameter: Meter
Antenna_Movement_Stopped[edit]
The stop position of the antenna tower.
Parameter: position
Unit parameter: Meter
Antenna_Movement_Percentage[edit]
The current percentage of the antenna tower movement from the start position to the end position
Parameter: percentage
Unit parameter: %
Antenna_Movement_Changing_Polarisation[edit]
TurnTable_Movement_Started[edit]
Starting of the movement of the turn table with the target position of the turn table.
Parameter: position
Unit parameter: Degrees
TurnTable_Movement_Stopped[edit]
The stop position of the turn table.
Parameter: position
Unit parameter: Degrees
TurnTable_Movement_Turning_Percentage[edit]
The current percentage of the turn table movement from the start position to the end position
Parameter: percentage
Unit parameter: %