RadiMationInterface.can: Difference between revisions
Line 55: | Line 55: | ||
'''Unit parameter:''' dBm | '''Unit parameter:''' dBm | ||
==Test_Amplitude_Modulation_Internal== | ==Test_Amplitude_Modulation_Internal== | ||
The modulation in the signal generator is configured as internal frequency modulation. | |||
'''Parameter1:''' mdFreqency | |||
'''Unit parameter1:''' Hz | |||
'''Parameter2:''' mdDepth | |||
'''Unit parameter2:''' % | |||
{{note|The modulation may not be active at this moment, [[#Test_Modulation_On|Test_Modulation_On]] is the event called when the modulation is turned on.}} | |||
==Test_Amplitude_Modulation_External== | ==Test_Amplitude_Modulation_External== | ||
The modulation in the signal generator is configured as external amplitude modulation. | |||
{{note|The modulation may not be active at this moment, [[#Test_Modulation_On|Test_Modulation_On]] is the event called when the modulation is turned on.}} | |||
==Test_Frequency_Modulation_Internal== | ==Test_Frequency_Modulation_Internal== | ||
==Test_Frequency_Modulation_External== | ==Test_Frequency_Modulation_External== |
Revision as of 10:06, 28 October 2010
The RadiMationInterface.can is an interface between the RadiMation software and CANoe and CANalyser.
By inserting this file inside your CANoe/CANalyser project you are able to extract information from RadiMation using CANoe/CANalyser.
You can download the file here
Explanation of available events/functions[edit]
Test_Frequency[edit]
The current frequency of the test, in other words the frequency of the signal generator.
Parameter: mdFreqMHz
Unit parameter: MHz
Test_Carrier_Level[edit]
The carrier level of the signal generator
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Forward_Power[edit]
The measured value of the forward power.
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Reflected_Power[edit]
The measured value of the reflected power.
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Average_Field[edit]
The measured value of the average field.
Parameter: mdFieldVm
Unit parameter: V/m
Test_Calculated_Field[edit]
The calculated value of the field based on the calibration file.
Parameter: mdFieldVm
Unit parameter: V/m
Test_Measured_Current[edit]
The measured value of the current.
Parameter: mdCurrentInmA
Unit parameter: mA
Test_Sensor_Power[edit]
The measured power of by the current sensor power meter.
Parameter: mdPowerIndBm
Unit parameter: dBm
Test_Amplitude_Modulation_Internal[edit]
The modulation in the signal generator is configured as internal frequency modulation.
Parameter1: mdFreqency
Unit parameter1: Hz
Parameter2: mdDepth
Unit parameter2: %
Note: | The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on. |
Test_Amplitude_Modulation_External[edit]
The modulation in the signal generator is configured as external amplitude modulation.
Note: | The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on. |
Test_Frequency_Modulation_Internal[edit]
Test_Frequency_Modulation_External[edit]
The modulation in the signal generator is configured as external frequency modulation.
Note: | The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on. |
Test_Pulse_Modulation_Internal[edit]
Test_Pulse_Modulation_External[edit]
The modulation in the signal generator is configured as external pulse modulation.
Note: | The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on. |
Test_Modulation_On[edit]
The currently configured modulation is turned on.
Test_Modulation_Off[edit]
The current configured modulation is turned off.
Antenna_Movement_Started[edit]
Starting of the movement of the antenna tower with the target position of the antenna tower.
Parameter: position
Unit parameter: Meter
Antenna_Movement_Stopped[edit]
The stop position of the antenna tower.
Parameter: position
Unit parameter: Meter
Antenna_Movement_Percentage[edit]
The current percentage of the antenna tower movement from the start position to the end position
Parameter: percentage
Unit parameter: %
Antenna_Movement_Changing_Polarisation[edit]
Changing the antenna polarisation.
Parameter: target
Unit parameter: unitless
When the target is 1 the antenna is changed to horizontal.
When the target is 2 the antenna is changed to vertical.
TurnTable_Movement_Started[edit]
Starting of the movement of the turn table with the target position of the turn table.
Parameter: position
Unit parameter: Degrees
TurnTable_Movement_Stopped[edit]
The stop position of the turn table.
Parameter: position
Unit parameter: Degrees
TurnTable_Movement_Turning_Percentage[edit]
The current percentage of the turn table movement from the start position to the end position
Parameter: percentage
Unit parameter: %