Template:Frequency window immunity: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
===Frequency window===
In the frequency window, the operator can enter a frequency range to be measured or select a frequency list.
When the Frequency range is selected, the following items can be entered:
{{ScreenElementDescriptionStart}}
{{ScreenElementDescriptionStart}}
{{ScreenElementDescription|Frequency Range|
{{ScreenElementDescription|Frequency Range|Sets the frequency specification to a {{ScreenElement|frequency range}}.}}
  {{ScreenElementDescription|Start|Sets {{ScreenElement|start}} frequency}}
{{ScreenElementDescription|Start|Sets {{ScreenElement|start}} frequency.}}
  {{ScreenElementDescription|Stop|Sets {{ScreenElement|stop}} frequency}}
{{ScreenElementDescription|End|Sets {{ScreenElement|end}} frequency.}}
  {{ScreenElementDescription|Step|
{{ScreenElementDescription|Step Fixed|Sets a fixed step size from start to end frequency.}}
    {{ScreenElementDescription|Fixed|Sets a fixed step size from start to stop frequency}}
{{ScreenElementDescription|Step Previous Frequency|Sets a logarithmic step size from start to stop frequency}}
    {{ScreenElementDescription|Previous Frequency|Sets a logarithmic step size from start to stop frequency}}
{{ScreenElementDescription|Starting From|Sets the start frequency for a logarithmic step from which the actual measurement frequencies will be calculated. the starting from frequency should be lower then the actual start frequency. The test will start at the first calculated frequency that is equal or higher then the specified start frequency.}}
    {{ScreenElementDescription|Starting From|Sets the start frequency for a logarithmic step from which the actual measurement frequencies will be calculated. the starting from frequency should be lower then the actual start frequency. The test will start at the first calculated frequency that is equal or higher then the specified start frequency.}}
  }}
}}
{{ScreenElementDescription|Frequency list|With {{ScreenElement|frequency list}} the operator can select a frequency list file by browsing to the file location. The frequencies inside the frequency list file will be measured.}}
{{ScreenElementDescription|Frequency list|With {{ScreenElement|frequency list}} the operator can select a frequency list file by browsing to the file location. The frequencies inside the frequency list file will be measured.}}
{{ScreenElementDescriptionEnd}}
{{ScreenElementDescriptionEnd}}

Latest revision as of 15:20, 14 March 2011

ScreenElementDescription.svg Frequency Range Sets the frequency specification to a frequency range.
ScreenElementDescription.svg Start Sets start frequency.
ScreenElementDescription.svg End Sets end frequency.
ScreenElementDescription.svg Step Fixed Sets a fixed step size from start to end frequency.
ScreenElementDescription.svg Step Previous Frequency Sets a logarithmic step size from start to stop frequency
ScreenElementDescription.svg Starting From Sets the start frequency for a logarithmic step from which the actual measurement frequencies will be calculated. the starting from frequency should be lower then the actual start frequency. The test will start at the first calculated frequency that is equal or higher then the specified start frequency.
ScreenElementDescription.svg Frequency list With frequency list the operator can select a frequency list file by browsing to the file location. The frequencies inside the frequency list file will be measured.