Release Notes/Solved items Version 2016.2.11: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
(Created page with '== RadiMation version 2016.2.11 == * #8217: Ability to set the R&S ESW26 Analyser number of points to a maximum of 32000')
 
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
== RadiMation version 2016.2.11 ==
== RadiMation version 2016.2.11 ==
* #7981: Device stays in remote after reaching the end frequency
* #8007: Turning of the MAHA turntable is not working
* #8051: ESIB 40 FFT mode cannot be active in zero span
* #8057: Harmonic Test Calibration with Aronia
* #8070: Driver: RadiSense 10 Field sensor
* #8075: Driver: Emtest CWS500N1 Signal Generator
* #8117: R&S ESPI 3 Impossible to get description string for this Error when opening ShowConfigurationDialog
* #8126: Driver: NoiseKen Amplifier
* #8128: Driver: EUT Monitor R&S UPV
* #8208: Frequency is not set in the PMM 8053A
* #8216: How to connect a Rohde & Schwarz NRP6A power sensor?
* #8217: Ability to set the R&S ESW26 Analyser number of points to a maximum of 32000
* #8217: Ability to set the R&S ESW26 Analyser number of points to a maximum of 32000
* #8231: Driver: Keysight Technologies 33612A Signal Generator
* #8242: Support 4 kHz option of RadiPower
* #8243: Unknown error in control of Climat Chamber
* #8247: Tektronix Oscilloscope returns No data or incorrect data was returned by the device
* #8250: Passive drivers CEATSA (ARSAT)
* #8251: Driver: Antenna tower controller ETS-Lindgren 2090 Positioning Controller
* #8252: Driver: Amplifier IFI S251-500
* #8253: Driver: Amplifier IFI T2575-500
* #8256: Driver: Powermeter NRP-Z55/NRP-Z5
* #8257: Crash with Fluke 8845A Multimeter
* #8259: Driver: special RadiSense justation device driver
* #8278: What is the latest RadiMation version running on Windows XP?
* #8286: Extend R&S ESR3 driver to allow selection of CISPR-Average or (old-)Average as Average detector
* #8289: Extend R&S ESPI7 driver to allow selection of CISPR-Average or (old-)Average as Average detector
* #8291: Driver: CWS 500N3 as Amplifier
* #8292: Driver: CWS 500N3 as Coupler
* #8293: Driver: CWS 500N3 as Powermeter (in V mode)
* #8294: Driver: CWS 500N3 as Current sensor (in I mode) as Multimeter
* #8295: Magnetic field testing ISO 11452-8 using the EMTest CWS500N3
* #8298: Driver: Virtual ESD device driver
* #8314: Communication is getting out of sync using a Configurable Antenna Tower driver
* #8323: Driver: is the Frankonia EFS 10 (EFS-100) Field sensor supported?
* #8326: Unexpected responses from RGN device seems to out sync and disturb communication causes "'Setting the output raised an error"
* #8328: LumiLoop LS Probe raises "Setting the frequency raised an error"
* #8333: How to tweak monitoring Field sensor measurements configuration for more reliable measurements?
* #8336: Low field strengths values are increasing signal generator carrier level to the maximum during 61000-4-3 calibration
* #8339: Are previous RadiMation version still usable after updating to a newer RadiMation version?
* #8343: Signal generator drivers (e.g. RGN0230A) raising Unknown Device Driver error
* #8345: Session for reconfiguration of the complete RadiMation installation
* #8348: PMM 8053A: Setting or enabling the frequency correction feature raised an error
* #8350: RF Relay Matrix Unit RFM-S3A3CILR and RFM-S2A2CILR and RFM-E521_231_241
* #8351: R&S ESI 26 Specific System Error: -200 Execution error; Option not available; SCAN1:INP:ATT 50 DB
* #8353: Adjust the RadiSense justation driver having the calculation accepting Signal Generator power levels
* #8367: RadiLog description containing a ";" removes 1 space
* #8369: Amplifier IFI S251-500 Not all bytes are written to the GPIB-Board within the timeout period (GPIB: EABO)
* #8370: Amplifier IFI T2575-500 Not all bytes are written to the GPIB-Board within the timeout period (GPIB: EABO)
* #8373: How to configure the used (EMI) filter of the equipment?

Latest revision as of 12:37, 7 September 2017

RadiMation version 2016.2.11[edit]

  • #7981: Device stays in remote after reaching the end frequency
  • #8007: Turning of the MAHA turntable is not working
  • #8051: ESIB 40 FFT mode cannot be active in zero span
  • #8057: Harmonic Test Calibration with Aronia
  • #8070: Driver: RadiSense 10 Field sensor
  • #8075: Driver: Emtest CWS500N1 Signal Generator
  • #8117: R&S ESPI 3 Impossible to get description string for this Error when opening ShowConfigurationDialog
  • #8126: Driver: NoiseKen Amplifier
  • #8128: Driver: EUT Monitor R&S UPV
  • #8208: Frequency is not set in the PMM 8053A
  • #8216: How to connect a Rohde & Schwarz NRP6A power sensor?
  • #8217: Ability to set the R&S ESW26 Analyser number of points to a maximum of 32000
  • #8231: Driver: Keysight Technologies 33612A Signal Generator
  • #8242: Support 4 kHz option of RadiPower
  • #8243: Unknown error in control of Climat Chamber
  • #8247: Tektronix Oscilloscope returns No data or incorrect data was returned by the device
  • #8250: Passive drivers CEATSA (ARSAT)
  • #8251: Driver: Antenna tower controller ETS-Lindgren 2090 Positioning Controller
  • #8252: Driver: Amplifier IFI S251-500
  • #8253: Driver: Amplifier IFI T2575-500
  • #8256: Driver: Powermeter NRP-Z55/NRP-Z5
  • #8257: Crash with Fluke 8845A Multimeter
  • #8259: Driver: special RadiSense justation device driver
  • #8278: What is the latest RadiMation version running on Windows XP?
  • #8286: Extend R&S ESR3 driver to allow selection of CISPR-Average or (old-)Average as Average detector
  • #8289: Extend R&S ESPI7 driver to allow selection of CISPR-Average or (old-)Average as Average detector
  • #8291: Driver: CWS 500N3 as Amplifier
  • #8292: Driver: CWS 500N3 as Coupler
  • #8293: Driver: CWS 500N3 as Powermeter (in V mode)
  • #8294: Driver: CWS 500N3 as Current sensor (in I mode) as Multimeter
  • #8295: Magnetic field testing ISO 11452-8 using the EMTest CWS500N3
  • #8298: Driver: Virtual ESD device driver
  • #8314: Communication is getting out of sync using a Configurable Antenna Tower driver
  • #8323: Driver: is the Frankonia EFS 10 (EFS-100) Field sensor supported?
  • #8326: Unexpected responses from RGN device seems to out sync and disturb communication causes "'Setting the output raised an error"
  • #8328: LumiLoop LS Probe raises "Setting the frequency raised an error"
  • #8333: How to tweak monitoring Field sensor measurements configuration for more reliable measurements?
  • #8336: Low field strengths values are increasing signal generator carrier level to the maximum during 61000-4-3 calibration
  • #8339: Are previous RadiMation version still usable after updating to a newer RadiMation version?
  • #8343: Signal generator drivers (e.g. RGN0230A) raising Unknown Device Driver error
  • #8345: Session for reconfiguration of the complete RadiMation installation
  • #8348: PMM 8053A: Setting or enabling the frequency correction feature raised an error
  • #8350: RF Relay Matrix Unit RFM-S3A3CILR and RFM-S2A2CILR and RFM-E521_231_241
  • #8351: R&S ESI 26 Specific System Error: -200 Execution error; Option not available; SCAN1:INP:ATT 50 DB
  • #8353: Adjust the RadiSense justation driver having the calculation accepting Signal Generator power levels
  • #8367: RadiLog description containing a ";" removes 1 space
  • #8369: Amplifier IFI S251-500 Not all bytes are written to the GPIB-Board within the timeout period (GPIB: EABO)
  • #8370: Amplifier IFI T2575-500 Not all bytes are written to the GPIB-Board within the timeout period (GPIB: EABO)
  • #8373: How to configure the used (EMI) filter of the equipment?