Release Notes/Solved items Version 2017.1.4: Difference between revisions
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
== RadiMation version 2017.1.4 == | == RadiMation version 2017.1.4 == | ||
* #6093: Turntable CO3000 is not moving when setting it to make a full turn from 0 till 360 degrees | |||
* #8207: Configurable Device driver frequencies with different units | |||
* #8244: Climat typo it should be Climate | * #8244: Climat typo it should be Climate | ||
* #8301: Unhandled exception access to the path ErrorModeFile.radilog is denied | * #8301: Unhandled exception access to the path ErrorModeFile.radilog is denied | ||
* #8322: RPR2006C overranges during CDN voltage calibration | |||
* #8382: ODBC customer database is not working anymore | * #8382: ODBC customer database is not working anymore | ||
* #8383: Store RADIMAT_SESSION.LOG in a PC local temporary folder | * #8383: Store RADIMAT_SESSION.LOG in a PC local temporary folder | ||
Line 7: | Line 10: | ||
* #8397: Searching for a customer in the customer database closes the window before the customer can be selected | * #8397: Searching for a customer in the customer database closes the window before the customer can be selected | ||
* #8399: Loading a multiband immunity test is not possible, unable to create VSWRGatherer | * #8399: Loading a multiband immunity test is not possible, unable to create VSWRGatherer | ||
* #8416: Agilent N9000A (version A.07.06) Error with GPIB | |||
* #8426: Unable to select correct OPC channels for AD converter. | |||
* #8435: Allow control of CANoe 9.0.65 (SP2) | |||
* #8443: Driver: Amplifier BLMA 1060-50 | |||
* #8458: Unable to connect to radigen RADIGEN0230A |
Revision as of 08:46, 11 October 2017
RadiMation version 2017.1.4[edit]
- #6093: Turntable CO3000 is not moving when setting it to make a full turn from 0 till 360 degrees
- #8207: Configurable Device driver frequencies with different units
- #8244: Climat typo it should be Climate
- #8301: Unhandled exception access to the path ErrorModeFile.radilog is denied
- #8322: RPR2006C overranges during CDN voltage calibration
- #8382: ODBC customer database is not working anymore
- #8383: Store RADIMAT_SESSION.LOG in a PC local temporary folder
- #8389: Received power is rounded in Antenna Scan EUT Calibration
- #8397: Searching for a customer in the customer database closes the window before the customer can be selected
- #8399: Loading a multiband immunity test is not possible, unable to create VSWRGatherer
- #8416: Agilent N9000A (version A.07.06) Error with GPIB
- #8426: Unable to select correct OPC channels for AD converter.
- #8435: Allow control of CANoe 9.0.65 (SP2)
- #8443: Driver: Amplifier BLMA 1060-50
- #8458: Unable to connect to radigen RADIGEN0230A