(Created page with "== RadiMation version 2019.1.10 == * #10112: Radimation crash when opening the advanced dialog of a horn-antenna driver for a second time. * #10366: Driver: Receiver/Analyser...") |
|||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
== RadiMation version 2019.1.10 == | == RadiMation version 2019.1.10 (BETA release) == | ||
* #10112: Radimation crash when opening the advanced dialog of a horn-antenna driver for a second time. | * #10112: Radimation crash when opening the advanced dialog of a horn-antenna driver for a second time. | ||
* #10357: Maturo NCD tower and turntable | |||
* #10366: Driver: Receiver/Analyser Tektronix RSA6114A | * #10366: Driver: Receiver/Analyser Tektronix RSA6114A | ||
* #10390: Driver: Tektronix TDS5054B AD Converter Driver | |||
* #10399: EM-TEST UCS500N7 - Surge test is not working | * #10399: EM-TEST UCS500N7 - Surge test is not working | ||
* #10399: EM-TEST UCS500N7 - Surge test is not working | * #10399: EM-TEST UCS500N7 - Surge test is not working | ||
Line 25: | Line 27: | ||
* #10612: Driver: R&S USP220 switch matrix with module B107 | * #10612: Driver: R&S USP220 switch matrix with module B107 | ||
* #10616: Rohde & Schwarz SMB 100A: Specific System Error: -222,"Data out of range; | * #10616: Rohde & Schwarz SMB 100A: Specific System Error: -222,"Data out of range; | ||
* #10583: SMB 100A: Specific System Error -222, Data Out of Range: SOURCE: POWER 40.3894 DBM | |||
* #10626: Error at SMF100A command in our driver | * #10626: Error at SMF100A command in our driver | ||
* #10627: PMM EP601 Not using selected filter settings | * #10627: PMM EP601 Not using selected filter settings | ||
* #10630: Keysight technologies N5172B: Specific system error: -410, "Query INTERRUPTED" | * #10630: Keysight technologies N5172B: Specific system error: -410, "Query INTERRUPTED" |
Latest revision as of 10:58, 6 January 2020
RadiMation version 2019.1.10 (BETA release)[edit]
- #10112: Radimation crash when opening the advanced dialog of a horn-antenna driver for a second time.
- #10357: Maturo NCD tower and turntable
- #10366: Driver: Receiver/Analyser Tektronix RSA6114A
- #10390: Driver: Tektronix TDS5054B AD Converter Driver
- #10399: EM-TEST UCS500N7 - Surge test is not working
- #10399: EM-TEST UCS500N7 - Surge test is not working
- #10417: Eventlog is showing an additional column 'Setting ID' with: 'DARE.RadiMat.clsDataIdentifierSetting'
- #10441: Polarity of test generator
- #10422: DARE!! Instruments RPR2006C: Timeout expired before operation completed.
- #10494: Driver: Pearson Model 101
- #10524: Driver: DARE!! Instruments RGN2006A
- #10531: MK Messtechnik - Initialization before AND After each test
- #10537: SMB 100A: Specific System Error -222, Data Out of Range
- #10541: Driver: DARE!! Instruments RGN2400A
- #10570: RI Substitution Single Band - modulation: Pulse states"With Voltage conservation"
- #10573: Driver: RadiGen 2400A changed commands.
- #10576: Driver for monitor input for the NSG4070
- #10578: EMTEST UCS500N7 - Surge test is not working when controlled remote
- #10582: Rohde & Schwarz ESI 40 Input 2: Specific System Error: -222,"Data out of range; SCAN1:BAND:RES 1 KHZ
- #10585: DARE!! Instruments RSW1021N: Wrong command Accepted use of data: True User
- #10596: The enhanced status window is popping up during a band switch.
- #10598: ||SELECT [Frequency (MHz)], [RBW: 9 kHz, Neutral Max Peak (dBµV)] FROM RBW: 9 kHz, Neutral Max Peak TABLE|| does not resolve.
- #10606: Driver: Wavecontrol SMP2
- #10608: Driver: R&S BBL200
- #10611: CI- When starting test we get the error "Teseq NSG 4070 Driver function not implemented"
- #10612: Driver: R&S USP220 switch matrix with module B107
- #10616: Rohde & Schwarz SMB 100A: Specific System Error: -222,"Data out of range;
- #10583: SMB 100A: Specific System Error -222, Data Out of Range: SOURCE: POWER 40.3894 DBM
- #10626: Error at SMF100A command in our driver
- #10627: PMM EP601 Not using selected filter settings
- #10630: Keysight technologies N5172B: Specific system error: -410, "Query INTERRUPTED"