DO-160: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
Line 29: Line 29:
* Chapter 21.5: Radiated RF emissions
* Chapter 21.5: Radiated RF emissions


Testing in accordance with Section 21 can be performed by using {{RadiMation}}. However the The reverberation chamber procedure as described in chapter 21.6 is not yet fully supported by {{RadiMation}}.
Testing in accordance with Section 21 can be performed by using {{RadiMation}}. However the reverberation chamber procedure as described in chapter 21.6 is not yet fully supported by {{RadiMation}}.


= Other sections =
= Other sections =

Revision as of 11:53, 4 April 2022

The RTCA DO-160G is also known as ISO 7137. It is also the same as EUROCAE ED-14G.

RTCA DO-357 is the userguide that provides additional explanations regarding the contents of DO-160G.

The DO-160 revision G is released at December 8, 2010. It consists of several sections, numbered from 4.0 to 26.0.

RadiMation® also does support the 1 Hz on/off modulation. The 'Software Pulse modulation' setting can be used for such low frequency pulse modulations.

Section 18[edit]

Title of section 18: Audio Frequency Conducted Susceptibility

  • Chapter 18.0: Audio Frequency Conducted Susceptibility - Power Inputs.

Testing in accordance with Section 18 can be performed by using RadiMation®.

Section 20[edit]

Title of section 20: Radio Frequency Susceptibility

  • Conducted Susceptibility is similar to MIL-STD CS114
  • Radiated Susceptibility is similar to MIL-STD RS103

Testing in accordance with Section 20 can be performed by using RadiMation®. However the The reverberation chamber procedure is not yet fully supported by RadiMation®.

Section 21[edit]

Title of section 21: Emission of Radio Frequency Energy

  • Chapter 21.4: Conducted RF emissions
  • Chapter 21.5: Radiated RF emissions

Testing in accordance with Section 21 can be performed by using RadiMation®. However the reverberation chamber procedure as described in chapter 21.6 is not yet fully supported by RadiMation®.

Other sections[edit]

The following sections are also EMC related, but have not yet been evaluated

  • Section 15.0 - Magnetic effect
  • Section 16.0 - Power input
  • Section 17.0 - Voltage spike
  • Section 19.0 - Induced signal susceptibility
  • Section 22.0 - Lightning induced Transient susceptibility
  • Section 23.0 - Lightning Direct effects
  • Section 25.0 - Electrostatic discharge

Links[edit]