Because the RBW values have a different values in these bands the test needs to be split the test into multiple bands:
==Frequency span with multiple RBW values setup==


Band A: 9 kHz - 150 kHz (200 Hz)
==Solution==
Band B: 150 kHz - 30 MHz (9 kHz)
Because the RBW values have a different values in these bands the test needs to be split the test into multiple bands or separate tests:
Band C: 30 MHz - 1 GHz (120 kHz)
 
* Band A: 9 kHz - 150 kHz (200 Hz)
* Band B: 150 kHz - 30 MHz (9 kHz)
* Band C: 30 MHz - 1 GHz (120 kHz)
 
[[Category:RadiMation]]
[[Category:RadiMation Error]]

Latest revision as of 13:03, 13 April 2022

Frequency span with multiple RBW values setup[edit]

Solution[edit]

Because the RBW values have a different values in these bands the test needs to be split the test into multiple bands or separate tests:

  • Band A: 9 kHz - 150 kHz (200 Hz)
  • Band B: 150 kHz - 30 MHz (9 kHz)
  • Band C: 30 MHz - 1 GHz (120 kHz)