=== Input Test level: Power closed loop method ===
==== Input: Power ====
[[file:TestLevel-Power-input.png]]
[[file:TestLevel-Power-input.png]]
{{ScreenElementDescriptionStart}}
{{ScreenElementDescription|Description|A field to enter a description for the power test level method being configured.}}
{{ScreenElementDescription|Constant Power|A test level option where the power is kept constant at a specified level, in this case, -100.0 dBm.}}
{{ScreenElementDescription|Variable Power|An option to set a range or variable power level for testing. This option is disabled in the image.}}
{{ScreenElementDescription|Signal Gen. Level (Pin)|A power method that uses the signal generator level (Pin) as the reference for power measurement.}}
{{ScreenElementDescription|Forward Power (Pfwd)|A power method that uses the forward power (Pfwd) as the reference for power measurement.}}
{{ScreenElementDescription|Net-Power (Pfwd - Prev)|A power method that calculates net power by subtracting the previous power level (Prev) from the forward power (Pfwd).}}
{{ScreenElementDescription|Tolerance|A field to set a tolerance level for power measurement in dB, which defines the acceptable variation range.}}

Latest revision as of 16:17, 12 November 2024

Input: Power[edit]

TestLevel-Power-input.png

ScreenElementDescription.svg Description A field to enter a description for the power test level method being configured.
ScreenElementDescription.svg Constant Power A test level option where the power is kept constant at a specified level, in this case, -100.0 dBm.
ScreenElementDescription.svg Variable Power An option to set a range or variable power level for testing. This option is disabled in the image.
ScreenElementDescription.svg Signal Gen. Level (Pin) A power method that uses the signal generator level (Pin) as the reference for power measurement.
ScreenElementDescription.svg Forward Power (Pfwd) A power method that uses the forward power (Pfwd) as the reference for power measurement.
ScreenElementDescription.svg Net-Power (Pfwd - Prev) A power method that calculates net power by subtracting the previous power level (Prev) from the forward power (Pfwd).
ScreenElementDescription.svg Tolerance A field to set a tolerance level for power measurement in dB, which defines the acceptable variation range.