(Created page with "Raditeq RadiSense EUT Controller: The current version of RadiMation does not support attaching correction via the RadiSense EUT Controller. Consider using a newer version of RadiMation (2025.2.1 or higher) or removing the device driver from the test site.") |
No edit summary |
||
| Line 1: | Line 1: | ||
= RadiSense EUT Controller Error = | |||
The current version of {{RadiMation}} does not support attaching correction via the RadiSense EUT Controller. Consider using a newer version of {{RadiMation}} (2025.2.1 or higher) or removing the device driver from the test site. | |||
== Solutions == | |||
* Update to the newer {{RadiMation}} version. | |||
* Remove device driver from the test-site. | |||
[[Category:RadiMation Error]] | |||
[[Category:RadiMation]] | |||
Latest revision as of 08:35, 8 December 2025
RadiSense EUT Controller Error[edit]
The current version of RadiMation® does not support attaching correction via the RadiSense EUT Controller. Consider using a newer version of RadiMation® (2025.2.1 or higher) or removing the device driver from the test site.
Solutions[edit]
- Update to the newer RadiMation® version.
- Remove device driver from the test-site.