The '''ISO11452-4''' standard describes the | The '''ISO11452-4''' standard describes the testing and measurement techniques for Bulk current injection (BCI). | ||
=Test method in short= | |||
Increase the forward power applied to the current injection probe and measure the injected current (Iref) until | |||
either | |||
*The measured current reaches the specified test level, or | |||
*The forward power reaches the power limit PCW limit. | |||
= Supported by {{RadiMation}}?= | |||
This method is supported by RadiMation. | |||
[[Category:Standard]] | [[Category:Standard]] |
Latest revision as of 20:19, 5 October 2024
The ISO11452-4 standard describes the testing and measurement techniques for Bulk current injection (BCI).
Test method in short[edit]
Increase the forward power applied to the current injection probe and measure the injected current (Iref) until either
- The measured current reaches the specified test level, or
- The forward power reaches the power limit PCW limit.
Supported by RadiMation®?[edit]
This method is supported by RadiMation.