Talk:RadiMation Application Note 120: Difference between revisions
Jump to navigation
Jump to search
(→Ticket) |
No edit summary |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Ticket == | == Ticket == | ||
Also see: #9486 | Also see: #9486. | ||
== Pictures == | == Pictures == | ||
For the pictures of the schematic setup, see the powerpoint file in: | |||
[svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx" | |||
Pictures of calibration setup: | Pictures of calibration setup: | ||
signal generator - connector - connector - analyser as powermeter | signal generator - connector - connector - analyser as powermeter | ||
Picture of eut setup: | Picture of eut setup: | ||
Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter | Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter | ||
== Required levels == | == Required levels == | ||
=== BMW === | === BMW [[GS 95002-3]] === | ||
* Signal generator level: minimum 0 dBm | * Signal generator level: minimum 0 dBm | ||
* Analyser: 120 kHz RBW | * Analyser: 120 kHz RBW | ||
Line 19: | Line 23: | ||
=== | === [[CISPR 25]] === | ||
* Signal generator level: recommended: 0 dBm | * Signal generator level: recommended: 0 dBm | ||
* Minimum number of points: 401 points | * Minimum number of points: 401 points | ||
* Frequency step: logarithmic | * Frequency step: logarithmic | ||
== Review Status == | |||
JORO: Reviewed. [[User:Joro|Joro]] ([[User talk:Joro|talk]]) 22:12, 10 April 2019 (CEST) |
Latest revision as of 20:12, 10 April 2019
Ticket[edit]
Also see: #9486.
Pictures[edit]
For the pictures of the schematic setup, see the powerpoint file in: [svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"
Pictures of calibration setup:
signal generator - connector - connector - analyser as powermeter
Picture of eut setup:
Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter
Required levels[edit]
BMW GS 95002-3[edit]
- Signal generator level: minimum 0 dBm
- Analyser: 120 kHz RBW
- Frequency step: logarithmic
- Frequency step width: max 500 kHz
- Freq-range: 0.10 MHz - 1000 MHz
CISPR 25[edit]
- Signal generator level: recommended: 0 dBm
- Minimum number of points: 401 points
- Frequency step: logarithmic