== Ticket ==
== Ticket ==
Also see: #9486:
Also see: #9486.


== Pictures ==
== Pictures ==
For the pictures of the schematic setup, see the powerpoint file in:
[svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"
Pictures of calibration setup:
Pictures of calibration setup:
signal generator - connector - connector - analyser as powermeter
signal generator - connector - connector - analyser as powermeter


Picture of eut setup:
Picture of eut setup:
Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter
Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter


== Required levels ==
== Required levels ==
=== BMW ===
=== BMW [[GS 95002-3]] ===
* Signal generator level: minimum 0 dBm
* Signal generator level: minimum 0 dBm
* Analyser: 120 kHz RBW
* Analyser: 120 kHz RBW
Line 19: Line 23:




=== CISPR25 ===
=== [[CISPR 25]] ===
* Signal generator level: recommended: 0 dBm
* Signal generator level: recommended: 0 dBm
* Minimum number of points: 401 points
* Minimum number of points: 401 points
* Frequency step: logarithmic
* Frequency step: logarithmic
== Review Status ==
JORO: Reviewed. [[User:Joro|Joro]] ([[User talk:Joro|talk]]) 22:12, 10 April 2019 (CEST)

Latest revision as of 20:12, 10 April 2019

Ticket[edit]

Also see: #9486.

Pictures[edit]

For the pictures of the schematic setup, see the powerpoint file in: [svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"

Pictures of calibration setup:

signal generator - connector - connector - analyser as powermeter

Picture of eut setup:

Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter

Required levels[edit]

BMW GS 95002-3[edit]

  • Signal generator level: minimum 0 dBm
  • Analyser: 120 kHz RBW
  • Frequency step: logarithmic
  • Frequency step width: max 500 kHz
  • Freq-range: 0.10 MHz - 1000 MHz


CISPR 25[edit]

  • Signal generator level: recommended: 0 dBm
  • Minimum number of points: 401 points
  • Frequency step: logarithmic


Review Status[edit]