CISPR 25: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
The title of this standard is: "Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers" | The title of this standard is: "Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers" | ||
The last known edition is edition | The last known edition is edition 5.0, which is released on 2021-12. | ||
This standard is also known as the EN 55025. | |||
== Related {{RadiMation}} Application Notes == | == Related {{RadiMation}} Application Notes == | ||
In | In Annex I of the CISPR 25, the determination of HV-LV Coupling attenuation is described. There are two methods described to determine this coupling attenuation: | ||
* Network analyser measurement, which is explained in [[RadiMation Application Note 120]]. | |||
* Injecting a signal, and measure the injected signal on the low voltage side, which is explained in [[RadiMation Application Note 131]]. | |||
== Links == | == Links == | ||
* IEC webstore: https://webstore.iec.ch/publication/ | * IEC webstore: https://webstore.iec.ch/publication/64645 | ||
[[Category:Standard]] | [[Category:Standard]] |
Latest revision as of 20:13, 20 February 2023
The CISPR 25 standard describes how EMC measurements are performed on motor vehicles. The title of this standard is: "Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers"
The last known edition is edition 5.0, which is released on 2021-12.
This standard is also known as the EN 55025.
Related RadiMation® Application Notes[edit]
In Annex I of the CISPR 25, the determination of HV-LV Coupling attenuation is described. There are two methods described to determine this coupling attenuation:
- Network analyser measurement, which is explained in RadiMation Application Note 120.
- Injecting a signal, and measure the injected signal on the low voltage side, which is explained in RadiMation Application Note 131.
Links[edit]
- IEC webstore: https://webstore.iec.ch/publication/64645