Talk:RadiMation Application Note 120: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
 
(One intermediate revision by the same user not shown)
Line 15: Line 15:


== Required levels ==
== Required levels ==
=== BMW ===
=== BMW [[GS 95002-3]] ===
* Signal generator level: minimum 0 dBm
* Signal generator level: minimum 0 dBm
* Analyser: 120 kHz RBW
* Analyser: 120 kHz RBW
Line 23: Line 23:




=== CISPR25 ===
=== [[CISPR 25]] ===
* Signal generator level: recommended: 0 dBm
* Signal generator level: recommended: 0 dBm
* Minimum number of points: 401 points
* Minimum number of points: 401 points
* Frequency step: logarithmic
* Frequency step: logarithmic
== Review Status ==
JORO: Reviewed. [[User:Joro|Joro]] ([[User talk:Joro|talk]]) 22:12, 10 April 2019 (CEST)

Latest revision as of 20:12, 10 April 2019

Ticket[edit]

Also see: #9486.

Pictures[edit]

For the pictures of the schematic setup, see the powerpoint file in: [svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"

Pictures of calibration setup:

signal generator - connector - connector - analyser as powermeter

Picture of eut setup:

Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter

Required levels[edit]

BMW GS 95002-3[edit]

  • Signal generator level: minimum 0 dBm
  • Analyser: 120 kHz RBW
  • Frequency step: logarithmic
  • Frequency step width: max 500 kHz
  • Freq-range: 0.10 MHz - 1000 MHz


CISPR 25[edit]

  • Signal generator level: recommended: 0 dBm
  • Minimum number of points: 401 points
  • Frequency step: logarithmic


Review Status[edit]

JORO: Reviewed. Joro (talk) 22:12, 10 April 2019 (CEST)