|DLLFile=RADAD.DLL
|DeviceBrand=ETS-lindgren
|DeviceDriverName=VISIONTRXCONTROLLER
|DeviceType=VisionTRX
|HideAutoData=1
|SupportedDeviceTypes=16777280
}}
===EUT-Controller===
===EUT-Controller===
The VisionTRX EUT controller can be used to display test parameters by means of a screen overlay on the recorded video stream by the visionTRX software.<BR/>
The VisionTRX EUT controller can be used to display test parameters by means of a screen overlay on the recorded video stream by the visionTRX software.
The driver is able to send these test paramaters to the VisionTRX software by means of identifiers. These identifiers are bound to the text inputs configured in the VisionTRX software by the user.<BR/>The driver is able to signal that a test has started or stopped, doing so VisionTRX can be made aware that it must start or stop recording from the configured sources.<BR/>
 
The driver is also able to indicate the start and end of the dwelltime, doing so the visionTRX software can be configured to only capture video during the moment in time on which the EUT is influenced.<BR/>For more detailed information regarding the configuration of the VisionTRX software, please consult the VisionTRX manual.
The driver is able to send these test parameters to the VisionTRX software by means of identifiers. These identifiers are bound to the text inputs configured in the VisionTRX software by the user. The driver is able to signal that a test has started or stopped, doing so VisionTRX can be made aware that it must start or stop recording from the configured sources.
The driver is also able to indicate the start and end of the dwelltime, doing so the visionTRX software can be configured to only capture video during the moment in time on which the EUT is influenced.
 
For more detailed information regarding the configuration of the VisionTRX software, please consult the VisionTRX manual.


===EUT-Controller keywords===
===EUT-Controller keywords===
Line 38: Line 50:
{{ScreenElementDescriptionEnd}}
{{ScreenElementDescriptionEnd}}


The keywords mentioned above are set as the identifiers in the text objects configured in visionTRX.
The keywords mentioned above are set as the identifiers in the text objects configured in VisionTRX.
For more information regarding the configuration of text objects, please consult your visionTRX manual.
For more information regarding the configuration of text objects, please consult your VisionTRX manual.


=== Communication ===
=== Communication ===
The VisionTRX driver communicates over LAN.
The VisionTRX driver communicates using VISA LAN.</BR>
The following VISA resource identifier can be used: "TCPIP0::127.0.0.1::inst0::INSTR".</BR>


=== Supported version ===
=== Supported version ===
This driver has been verified using: VisionTRX 1.0.4.6
This driver has been verified using: VisionTRX 1.0.5.4
 
{{DeviceDriverInfo
|DLLFile=RADAD.DLL
|DeviceBrand=ETS-lindgren
|DeviceDriverName=VISIONTRX
|DeviceType=VisionTRX
|SupportedDeviceTypes=64
}}

Latest revision as of 12:24, 8 March 2022

The ETS-lindgren VisionTRX device driver is a AD ConverterEUT Controller which is supported by RadiMation®.   

EUT-Controller[edit]

The VisionTRX EUT controller can be used to display test parameters by means of a screen overlay on the recorded video stream by the visionTRX software.

The driver is able to send these test parameters to the VisionTRX software by means of identifiers. These identifiers are bound to the text inputs configured in the VisionTRX software by the user. The driver is able to signal that a test has started or stopped, doing so VisionTRX can be made aware that it must start or stop recording from the configured sources. The driver is also able to indicate the start and end of the dwelltime, doing so the visionTRX software can be configured to only capture video during the moment in time on which the EUT is influenced.

For more detailed information regarding the configuration of the VisionTRX software, please consult the VisionTRX manual.

EUT-Controller keywords[edit]

The test parameters and their corresponding keywords that the VisionTRX driver currently supports are.

Parameter Keyword
Frequency ID_Frequency
Field strength ID_Field_strength
Forward power ID_Forward_power
Reflected power ID_Reflected_power
Netto power ID_Netto_power
Carrier level ID_Carrier


ScreenElementDescription.svg Frequency Display the current frequency.
ScreenElementDescription.svg Field strength Display the current field strength.
ScreenElementDescription.svg Forward power Display the current forward power.
ScreenElementDescription.svg Reflected power Display the current reflected power.
ScreenElementDescription.svg Netto power Display the current netto power.
ScreenElementDescription.svg Carrier level Display the current carrier level.


The keywords mentioned above are set as the identifiers in the text objects configured in VisionTRX. For more information regarding the configuration of text objects, please consult your VisionTRX manual.

Communication[edit]

The VisionTRX driver communicates using VISA LAN.
The following VISA resource identifier can be used: "TCPIP0::127.0.0.1::inst0::INSTR".

Supported version[edit]

This driver has been verified using: VisionTRX 1.0.5.4