[[File:DeviceDriverRadiSenseUserCalibrationTab.png]]
{{anchor|User correction}}[[File:DeviceDriverRadiSenseUserCorrectionTab.png]]


The {{ScreenElement|User Calibration}} tab can be used to upload the data of an user calibration into the {{PAGENAME}}. This calibration data can be used by the probe internally to to correct the measured values.
The {{ScreenElement|User Correction}} tab can be used to upload the data of an user correction into the {{PAGENAME}}. This correction data can be used by the probe internally to to correct the measured values.
{{ScreenElementDescriptionStart}}
{{ScreenElementDescriptionStart}}
{{ScreenElementDescription|Use calibration correction if available|If this option is activated, and if a user calibration is stored in the probe, then the correction will be used by the probe itself, to internally correct the measured value with the user calibration data. If this option is off, no correction of the measured values will be done.}}
{{ScreenElementDescription|Use user correction if available|If this option is activated, and if a user correction is stored in the probe, then the correction will be used by the probe itself, to internally correct the measured value with the user calibration data. If this option is off, no correction of the measured values will be done.}}
{{ScreenElementDescription|Browse|Allows to select the correction file that contains the User Calibration data of the {{PAGENAME}}.}}
{{ScreenElementDescription|Browse|Allows to select the correction file that contains the user correction data of the {{PAGENAME}}.}}
{{ScreenElementDescription|Program calibration table|Starts the actual uploading of the calibration table. First some checks are performed, and if those checks are successful, the actual uploading is performed.}}
{{ScreenElementDescription|Program correction table|Starts the actual uploading of the correction table. First some checks are performed, and if those checks are successful, the actual uploading is performed.}}
{{ScreenElementDescription|Download correction table|Downloads the user correction table from the probe, if available. Then displays a 'Save As' prompt to save the table as a RadiMation correction file.}}
{{ScreenElementDescriptionEnd}}
{{ScreenElementDescriptionEnd}}
{{ReportGeneratorInfo|For more information on how to program the RadiSense 10 correction table, see https://wiki.radimation.com/wiki/index.php/RadiMation_Application_Note_135}}

Latest revision as of 09:27, 20 November 2025

DeviceDriverRadiSenseUserCorrectionTab.png

The User Correction tab can be used to upload the data of an user correction into the DeviceDriverRadiSenseUserCorrectionTab. This correction data can be used by the probe internally to to correct the measured values.

ScreenElementDescription.svg Use user correction if available If this option is activated, and if a user correction is stored in the probe, then the correction will be used by the probe itself, to internally correct the measured value with the user calibration data. If this option is off, no correction of the measured values will be done.
ScreenElementDescription.svg Browse Allows to select the correction file that contains the user correction data of the DeviceDriverRadiSenseUserCorrectionTab.
ScreenElementDescription.svg Program correction table Starts the actual uploading of the correction table. First some checks are performed, and if those checks are successful, the actual uploading is performed.
ScreenElementDescription.svg Download correction table Downloads the user correction table from the probe, if available. Then displays a 'Save As' prompt to save the table as a RadiMation correction file.
Report generator.png
For more information on how to program the RadiSense 10 correction table, see https://wiki.radimation.com/wiki/index.php/RadiMation_Application_Note_135