Release Notes/Solved items Version 5.5.3: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
(New page: == RadiMation version 5.5.3 == * #3218:)
 
Line 1: Line 1:
== RadiMation version 5.5.3 ==
== RadiMation version 5.5.3 ==
* #3218:
* #2797: Wrong limitation of forward power when using AM modulation.
* #2876: Surge test does not allow 180 degrees test.
* #2936: Tektronix TDS 544A: surpress error message.
* #3153: Improve selection of bands to be more 'the Windows way of doing it'.
* #3250: Driver for amplifier Milmega AS0104-100/100.
* #3255: Even if the option is disabled, Zoom-in is performed for RE Multiband.
* #3275: Time formating is not according to the pc settings.
* #3276: Driver: Current Clamps for installation.
* #3287: changing the test site in a save tsf is not detected correctly.
* #3311: In Limit Line definition, button Graph/Customize is present but not working.
* #3314: "STEP FREQUENCY" in generated report is empty.
* #3315: 180 degrees angle is missing at the Surge test field.
* #3327: PMM 9010 is giving error during the Init.
* #3328: Changes to the description of the limit line doesn't mark the file as changed.
* #3335: Driver: Hameg HM 8150.
* #3340: Rs-232 support for fluke 45.
* #3345: Driver: Agilent PSA 4440.
* #3346: Driver: BLWA 0810-100.
* #3348: impossible to work with surge test, tabs keep on changing.
* #3350: Engineer log in window is not unloaded correctly when false password is given.
* #3355: Driver: AR 2500A250A.
* #3358: Error message while opening ESD TSF file.
* #3365: SMB 100A is going to 0 dBm all the time.
* #3368: Crash when pressing markers in the graph customization window in a new installation.

Revision as of 08:57, 1 April 2009

RadiMation version 5.5.3[edit]

  • #2797: Wrong limitation of forward power when using AM modulation.
  • #2876: Surge test does not allow 180 degrees test.
  • #2936: Tektronix TDS 544A: surpress error message.
  • #3153: Improve selection of bands to be more 'the Windows way of doing it'.
  • #3250: Driver for amplifier Milmega AS0104-100/100.
  • #3255: Even if the option is disabled, Zoom-in is performed for RE Multiband.
  • #3275: Time formating is not according to the pc settings.
  • #3276: Driver: Current Clamps for installation.
  • #3287: changing the test site in a save tsf is not detected correctly.
  • #3311: In Limit Line definition, button Graph/Customize is present but not working.
  • #3314: "STEP FREQUENCY" in generated report is empty.
  • #3315: 180 degrees angle is missing at the Surge test field.
  • #3327: PMM 9010 is giving error during the Init.
  • #3328: Changes to the description of the limit line doesn't mark the file as changed.
  • #3335: Driver: Hameg HM 8150.
  • #3340: Rs-232 support for fluke 45.
  • #3345: Driver: Agilent PSA 4440.
  • #3346: Driver: BLWA 0810-100.
  • #3348: impossible to work with surge test, tabs keep on changing.
  • #3350: Engineer log in window is not unloaded correctly when false password is given.
  • #3355: Driver: AR 2500A250A.
  • #3358: Error message while opening ESD TSF file.
  • #3365: SMB 100A is going to 0 dBm all the time.
  • #3368: Crash when pressing markers in the graph customization window in a new installation.