Test method is short: | |||
Increase the forward power applied to the current injection probe and measure the injected current (Iref) until | |||
either | |||
*The measured current reaches the specified test level, or | |||
*The forward power reaches the power limit PCW limit. | |||
= supported by {{radimation}}= | |||
[[Category:Standard]] | [[Category:Standard]] |
Revision as of 14:15, 14 December 2009
The ISO11452-4 standard describes the Testing and measurement techniques for Bulk current injection (BCI).
Test method is short:
Increase the forward power applied to the current injection probe and measure the injected current (Iref) until
either
- The measured current reaches the specified test level, or
- The forward power reaches the power limit PCW limit.