Talk:RadiMation Application Note 120: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
Line 3: Line 3:


== Pictures ==
== Pictures ==
For the pictures of the schematic setup, see the powerpoint file in:
[svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"
Pictures of calibration setup:
Pictures of calibration setup:
signal generator - connector - connector - analyser as powermeter
signal generator - connector - connector - analyser as powermeter

Revision as of 13:04, 10 April 2019

Ticket

Also see: #9486:

Pictures

For the pictures of the schematic setup, see the powerpoint file in: [svn-trunk]:/Documentatie\TestAndMeasurementEquipment\HV-LV AttenuationCouplingSetups.pptx"

Pictures of calibration setup: signal generator - connector - connector - analyser as powermeter

Picture of eut setup: Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter


Required levels

BMW

  • Signal generator level: minimum 0 dBm
  • Analyser: 120 kHz RBW
  • Frequency step: logarithmic
  • Frequency step width: max 500 kHz
  • Freq-range: 0.10 MHz - 1000 MHz


CISPR25

  • Signal generator level: recommended: 0 dBm
  • Minimum number of points: 401 points
  • Frequency step: logarithmic