Talk:RadiMation Application Note 120: Difference between revisions
Jump to navigation
Jump to search
(Created page with "== Ticket == #9486:") |
(→Ticket) |
||
Line 1: | Line 1: | ||
== Ticket == | == Ticket == | ||
#9486: | Also see: #9486: | ||
== Pictures == | |||
Pictures of calibration setup: | |||
signal generator - connector - connector - analyser as powermeter | |||
Picture of eut setup: | |||
Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter | |||
== Required levels == | |||
=== BMW === | |||
* Signal generator level: minimum 0 dBm | |||
* Analyser: 120 kHz RBW | |||
* Frequency step: logarithmic | |||
* Frequency step width: max 500 kHz | |||
* Freq-range: 0.10 MHz - 1000 MHz | |||
=== CISPR25 === | |||
* Signal generator level: recommended: 0 dBm | |||
* Minimum number of points: 401 points | |||
* Frequency step: logarithmic |
Revision as of 13:43, 9 April 2019
Ticket[edit]
Also see: #9486:
Pictures[edit]
Pictures of calibration setup: signal generator - connector - connector - analyser as powermeter
Picture of eut setup: Signal generator - connector - HV adapter - EUT - LV Adapter - connector - analyser as powermeter
Required levels[edit]
BMW[edit]
- Signal generator level: minimum 0 dBm
- Analyser: 120 kHz RBW
- Frequency step: logarithmic
- Frequency step width: max 500 kHz
- Freq-range: 0.10 MHz - 1000 MHz
CISPR25[edit]
- Signal generator level: recommended: 0 dBm
- Minimum number of points: 401 points
- Frequency step: logarithmic