IEC 61000-4-21: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
(Created page with "__NOTOC__ The EN/IEC 61000-4-21 standard describes how Immunity and Emission measurements are performed in a reverberation chamber. The exact title of this st...")
 
No edit summary
Line 1: Line 1:
__NOTOC__
__NOTOC__
The [[EN]]/[[IEC]] 61000-4-21 standard describes how [[Immunity]] and [[Emission]] measurements are performed in a reverberation chamber.
The [[EN]]/[[IEC]] 61000-4-21 standard describes how [[Immunity]], [[Emission]] and other measurements are performed in a reverberation chamber.


The exact title of this standard is: "IEC 61000-4-21: Electromagnetic compatibility (EMC) - Part 4-21:
The exact title of this standard is: "IEC 61000-4-21: Electromagnetic compatibility (EMC) - Part 4-21:
Line 11: Line 11:
* ....
* ....
* ...
* ...
The field within the chamber is considered uniform if the standard deviation is lower than a predefined value.
{|class="wikitable"
!Frequency range
|below 100 MHz
|100 - 400 MHz
|above 400 MHz
|-
!Accepted standard deviation
|4 dB
|3 dB increasing linearly to 4 dB
|3 dB
|}
The specific measurements are described in several Annexes:
* Annex A:
* Annex B:
* Annex C:





Revision as of 14:52, 5 January 2023

The EN/IEC 61000-4-21 standard describes how Immunity, Emission and other measurements are performed in a reverberation chamber.

The exact title of this standard is: "IEC 61000-4-21: Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods"

This review is based on the 2011 version.

Some random remarks and notes:

  • ....
  • ...

The field within the chamber is considered uniform if the standard deviation is lower than a predefined value.

Frequency range below 100 MHz 100 - 400 MHz above 400 MHz
Accepted standard deviation 4 dB 3 dB increasing linearly to 4 dB 3 dB

The specific measurements are described in several Annexes:

  • Annex A:
  • Annex B:
  • Annex C: