RadiMation Application Note 106

From RadiWiki
Jump to navigation Jump to search

Powermeter parameter configuration

This application note describes how the measurement parameters of a Powermeter can be configured to get a fast and stable power measurement.

Each powermeter in {RadiMation} has a powermeter configuration tab in the device drivers. In this tab, the accuracy of measured power can be optimized. This function allows to make multiple measurement loop, and wait until the value is stable.


PowerMeterPanel.png


ScreenElementDescription.svg Pre Wait Time Wait time before starting the multiple measurement loop. Can be used to wait for a signal generator, and or amplifier to stabalize.
ScreenElementDescription.svg Measure The maximum ammount of measure times, for the multiple measurement loop
ScreenElementDescription.svg Wait Time The wait time before each measurement is taken, during the multiple measurements loop.
ScreenElementDescription.svg Max. Difference If the measured power between each measurement in the multiple measurement loop, is less than this value. The measured power is stable. The loop will stop.

The powermeter can be used in the test to regulate signal generator values. The powermeter can also be used as monitoring input channel. For each powermeter usage, the multiple measurement loop can be configured.