- #2079: Usage of Amplifier protection is not clear if correction file has wrong columns
- #2631: Changing the minimum attenuation value argument in the device driver is changing the set attenuation
- #4209: No frequency verification on correction file
- #4380: CI multiband: crash during changing the band
- #5071: N9010A is not recognized anymore Unknown system error
- #5505: Rounding issues of Correction values (COR) when copied to clipboard
- #5515: Different measurement results with Singleband and Multiband test for Fixed Power method
- #5647: Correction file doesn't allow logarithmic interpolation of the value
- #6101: Disable all menu and editable items of which an engineer has no rights
- #6736: Correction is remembered in Virtual Instrument Powermeter when the correction file is detached again
- #6984: Infinite regulation when amplifier is in noize region
- #6987: RadiLog in 64 bits
- #6996: Peak numbering for emmission measurements are not shown and can't be sorted
- #7015: Radiated Immunity variable power closed loop with current sensor is endless regulating at first point
- #7159: RadiLog crashes with out of memory during a big test
- #7161: 7th point in RI calibration
- #7288: RadiLog slow with big description
- #7393: 'Output boxes' is shown as 'Unknown device driver types' in the 'Devices' menu
- #7445: Reflected powermeter measurements are not corrected
- #7533: Multiband Ok button of 'Continue automatic mode settings' is disabled
- #7555: Duplicate other test description menu in the graphs menu
- #7579: Copying the information of the EUT Monitoring grid to clipboard causes crash
- #7581: Test description of the test is not visible in the test data
- #7594: Radilog Deleted log when closing test
- #7595: RadiLog cleared within sequence
- #7569: Usefull RadiLog default description when sending an error report
- #7597: RadiLog Error Report disappearing window after sending log
- #7617: Cancelling the closing of the VI Fieldsensor results in a not working window
- #7618: Export of time-graph doesn't export all the data
- #7621: Exporting Report Generator using different extentions for template as the output, causing error cannot open file
- #7627: Endless regulation at frequency point during RI Fixed power test
- #7649: ReportGenerator to much capital letters
- #7660: Adjusted Fieldstrength units are not used in the scaling of the VI graphs
- #7663: CONFDVDR deadlock when Access to the path (..) is denied error is raised
- #7688: Correction data is not correctly determined from unsorted correction file
- #7691: Exporting graph to LLF doesnt show the in graph
- #7692: Copying the EUT Monitoring table to the clipboard causes a crash
- #7719: Exporting AD channels
- #7725: Multiple cosmetic changes to prevent controls from being hidden when window is resized
- #7726: Unicode: EUT files with chinese characters in the filename are not loaded correctly
- #7729: RadiLog doesn't show full binary data strings
- #7734: Report Generator code Step Frequency for ConEmi absorbtion clamp
- #7735: Unicode: INI files in unicode
- #7748: Unicode: Test-Sites