Release Notes/Solved items Version 5.4.6

From RadiWiki
Jump to navigation Jump to search

RadiMation version 5.4.6[edit]

  • #341: The antenna cannot be polarized automatically in an immunity test
  • #545: Customer Database interface should also be able to search on customer name
  • #2224: Not possible to select two or more product standards for an EUT
  • #2788: Switch matrix so switch the filterbox inside the amplifier
  • #2858: product standard window does not support enter and delete button
  • #2859: product standard and basic standard in the configuration window does not support enter and delete button
  • #2882: The buttons on the EUT window section Cables do not have the same pictures as the EUT information items
  • #2883: The Add /edit /remove buttons on the AD channels are not the same / are not positioned the same as the other add/edit/remove buttons
  • #2956: Auto attenuator and ESU analyser driver doe not work
  • #2993: Saving a immunity multi band file is very slow
  • #3013: English spelling error in a menu item
  • #3037: ESU is slow with getting the data back in time domein scan
  • #3056: the property "RadiMation Version" in the Carad driver is left empty.
  • #3087: Manual contains a statement that a field/current check is done during the test initialization. This is not true
  • #3089: Isotroop is dutch. In english it is: Isotropic
  • #3118: Limit line is not displayed correctly when swapping from log to line view
  • #3119: The reference level is not reported correctly in the Mil std magnetic measurement
  • #3123: Filling the Testlevel in dBuV will cause the value to goto either 100 or 180 dBuV
  • #3132: HP83620A is going first to 0 dBm and then lower
  • #3133: dBpT/uV factor is not taken into account in the magnetic field test
  • #3135: Writing IPersistable files with a 1 MByte cache are stored corrupted on disk
  • #3137: ESU-40 preamp driver issue.
  • #3139: The proposed EUT filename, in Save As EUT, has all \ removed
  • #3149: OATS test is displayed but not selectable
  • #3155: Not all devices are checked for the frequency range
  • #3163: HP 33120 signal generator raises an error and beeps during initialization
  • #3171: Driver: Amplifiers
  • #3172: Driver: Couplers
  • #3173: Drivers: Injection devices
  • #3174: Driver: Cal jigs
  • #3177: AD Channel with a 'dBm' unit, is not shown on the same axis as a power-meter with the 'dBm' unit
  • #3179: Driver: Schwarzbeck NTFM 8134
  • #3181: Error message during read out of Fluke 8846A (Fluke 45 command set)