RadiMation Application Note 100

From RadiWiki
Jump to navigation Jump to search

Enhanced Status Window[edit]

It is possible to configure RadiMation in such a way that a several measurement parameters are shown in a larger font on a customized location. This functionality is called "enhanced status window", and can be configured in the RadiMation configuration dialog.

This Application Note will explain how the Enhanced Status Window settings can be configured in RadiMation®. It is used by the EMC test engineer to provide clear status information during automatic EMC testing.

At moment of writing the Enhanced Status Window is only implemented for the Singleband tests and will therefore not (correctly) work for the Multiband tests.

Configuration[edit]

The configure this feature or to completely enable or disable it, go from the RadiMation® main menu to:

   Menu.svg Configuration
      Menu.svg Configuration
         Menu.svg Enhanced Status Window

The following configuration window is shown:

Configuration Enhanced Status Window Empty.png

Adding parameters[edit]

The text box before the 'Add' button can be used to specify the name of a measurement parameter. By pressing the 'Add' button the measurement parameter will be added to the list above it. All the measurement parameters that are included in the list will be shown during the test in a separate window.

It is possible to add different parameters, which are available during a test. For example, the current frequency. To show the current frequency throughout the test, type "Frequency" in the text box and press the 'add' button. The item is now added to the list. It is possible to add this item multiple times, which will result that the information is also shown multiple times.

Modifying font[edit]

The 'Font' button can be used to specify the font, the color and the size of the text in which the measurement parameters will be shown. The colored box behind the 'Background color:' will be the background color of the window in which the measurement parameters will be shown.

List of parameters[edit]

Generic:

  • Frequency
  • Signal Power
  • Forward Power
  • Reflected Power
  • Modulation
  • Average Field
  • Calculated Field
  • Voltage
  • Calculated Voltage
  • Current
  • Calculated Current
  • Measured Magnetic Field
  • Generated Magnetic Field
  • Out Power
  • Harmonic Frequency
  • Received Power At Antenna
  • Desired Antenna Height
  • Progress Antenna Height
  • Power Offset Due To Conservation

AD-Converter:

  • AD Channel 1
  • AD Channel 2
  • AD Channel 3
  • AD Channel 4
  • AD Channel 5
  • AD Channel 6
  • AD Channel 7
  • AD Channel 8

Field sensor:

  • Field Sensor 1
  • Field Sensor 2
  • Field Sensor 3
  • Field Sensor 4
  • Field Sensor 5
  • Field Sensor 6
  • Field Sensor 7
  • Field Sensor 8