Release Notes/Solved items Version 2016.1.9

From RadiWiki
Jump to navigation Jump to search

RadiMation version 2016.1.9[edit]

  • #1828: Additional total max hold graph window
  • #1957: Wrong message when no impedance file is selected
  • #3001: Manual is missing information on how the corrections (and the to be used columns) should be used
  • #3444: LISN ESU User port lan device
  • #4975: Sorting of table frequency data in the Report is incorrect
  • #5815: Driver Agilent N1911A powermeter
  • #5863: Error File is not found: %s when opening TSF or after crash
  • #5994: Test initialization failed for Agilent N5181A-506 with Pulse Modulation option
  • #6177: CARAD EUT Controller driver raises Ethernet not connected errors
  • #6752: The Device Specific value 'Power' of the powermeter should be renamed to 'Uncorrected Power'
  • #6902: Keywords TEST SITE EMAIL ADDRESS and CLIENT EMAIL ADDRESS are not working anymore
  • #6933: Driver Luthi MDS 20 Absorbing Clamp
  • #6934: Driver EMCO 3158 Antenna
  • #6935: Driver CBL 6144 antenna
  • #6936: Driver ARA DRG 118a Antenna
  • #6944: Driver Holaday HI4422 FieldProbe
  • #6951: Driver Schaffner NSG 2070
  • #6961: Description for this error is not available is shown during startup
  • #6964: Ability to have Start and Stop Dwelltime events for the NI 6218 switch matrix
  • #6993: RadiGen RGN6000B Setting the output level raised an error
  • #7010: Use a NI USB6501 to switch between forward and reflected power
  • #7024: Problem solving for the test setup of a Conducted Immunity Mil Std Calibration
  • #7025: Driver Rohde & Schwarz ESW26
  • #7040: Marconi signal generator doesn't respond on *STB?
  • #7197: Driver Generic National Instruments Output Switch
  • #7275: Switching matrix OSP 120. Relay K11 on slot 3 doesn't switch
  • #7291: RadiGen RGN6000B HF Returns error: -222 Data out of range
  • #7298: TCPIP Communication is not working correctly for the TDEMI
  • #7304: TCPIP controlled TDEMI Powermeter raises a crossthread error message
  • #7311: Driver Aaronia Spectran HF-60100 V4 X
  • #7314: Insert additional frequencies
  • #7340: Driver AE Techron 7224
  • #7341: Driver OSR C21A8
  • #7342: Driver TESEQ CIP 8136
  • #7343: Driver Rohde & Schwarz ESW8
  • #7345: Driver Agilent 87405A pre-amplifier
  • #7346: Driver Agilent 34401A
  • #7348: Driver Agilent 54831B as oscilloscope
  • #7349: Driver Agilent 34401A
  • #7352: Driver Antenna Schwarzbeck BBHA 9120J
  • #7353: Driver Antenna Schwarzbeck STLP 9128ES
  • #7354: Driver Directional Coupler werlatone C7354
  • #7356: Driver AR 500W1000B
  • #7379: R&S NRP only channel a is working
  • #7381: R&S ESL6: Several GPIB communication problems
  • #7397: RadiField RFS1006B Returns Error 521. Driver 3 current out of range
  • #7403: Communication with plugin cards is lost
  • #7424: Keysight N9083A runs incredibly slow after 3.6 GHz in scanned receiver mode
  • #7433: Not all data is recorded in RE GTEM
  • #7461: Unable to use formula option in AD converter
  • #7466: RadiField RFS1006B Returns Error 560. Communication amplifiers failed
  • #7478: EFT/Surge and VDI Report Generator keywords overview
  • #7480: Question regarding R&S IMS device drivers
  • #7483: Update the RadiMation software requirements
  • #7486: RSW1024S Interlock: Not all bytes are written to the GPIB-Boadr within the timeout period
  • #7487: RadiField RFS1006B Returns Error 526. time out error GPIB
  • #7488: RadiField RFS1006B Returns Error 1087. Signal power went to high (-6dB) during power delivery test
  • #7493: RadiField RFS1006B Disconnecting error: No amplifier connected
  • #7494: Kalmus amplifiers cannot be controlled. GPIB: No listener on the bus
  • #7495: RadiField RFS1006B Power off after disconnecting device
  • #7502: Extend the IDocument interface to also return an unique IDataIdentifier
  • #7503: Change the implementation of IGraphElement::DataIdentifier to also use the IDataIdentifier of the data document as the parent IDataIdentifier
  • #7504: List of available graphs should use the IDataIdentifier of the graph element
  • #7508: End frequency is not correctly stored in an attenuation/gain system calibration
  • #7510: SetMicroSecondsDelay is ignored/not used when set from the 'AfterStreamConnectConfiguration'
  • #7516: NI DAQ Error 6009 Unable to keep up with the hardware acquisition
  • #7521: How can the complete graph data of the polar plot be exported as table data?
  • #7534: SMR40 driver slowed down in communication
  • #7538: How to disable the power delivery test?
  • #7539: Driver Antenna BBA 9106
  • #7541: Driver PowerSensor Agilent N1911A
  • #7543: Driver Antenna SBA 9113
  • #7547: The used and installed version of the NI GPIB Library should be logged in RadiLog
  • #7548: Setting the VISA communication setting to the Visa-ID is automatically being changed to RS-232
  • #7550: Driver Broadband Preamplifier Schwarzbeck BBV 9743
  • #7556: Extend the license that the user agrees that RadiLog and other reported gathered data being send might contain confidential content
  • #7558: Driver Keysight EXG N5173B signal generator
  • #7562: Driver SG6000 Signal Generator
  • #7564: Driver Measuring amplifier B&K 2636 Analog, 1 channel (via GPIB now)
  • #7570: Driver Directional Coupler Warlatone C9475
  • #7571: Driver Teseq CDN M016S
  • #7572: Driver Teseq CDN S501AS
  • #7573: Driver CDN S751AS
  • #7574: Driver Werlatone C5982 Dual Directional Coupler
  • #7577: Easy merge of multiple EUT Attenuation/Gain corrections to one correction
  • #7583: ETS-Lindgren HI-6053 error No match was found in the specified regular expression
  • #7584: Driver Generic NI DAQ mx AD Converter device driver
  • #7587: How to configure a limitation on power during a DO-160G/ED-14G BCI test?