Monitoring input channel setup
Monitoring input channel setup
Contents
General
The Monitoring input channel setup window can be opened by opening a new or existing EUT file:
Then select the 'Monitoring input channels' panel. This window enables the end-user to configure the used AD-Converter during the test:
Settings
![]() |
Enter the description of the device. E.g. use the brand and/or identification number. |
![]() |
From the dropdown the used AD-Converter driver can be selected. |
![]() |
Enter the unit corresponding to the values which will be retrieved from the device. |
Calculation
![]() |
RadiMation will not apply any additional calculations to the value the device driver is returning. |
![]() |
RadiMation will additionally apply the specified offset to the retrieved value by the device driver. Similar to the formula (offset+x). |
![]() |
RadiMation will additionally apply the specified multiply factor to the retrieved value by the device driver. Similar to the formula (multiply factor*x). |
![]() |
RadiMation will not apply any additional calculations to the value the device driver is returning. |
![]() |
RadiMation will additionally apply the specified formula to the retrieved value by the device driver. |
The formula is using the powerful Python engine for maximum flexibility.
You can find the math functions on: https://docs.python.org/2/library/math.html
The following example will multiply the AD value by 2. And add (9^0.5)==(√9)==3
It is needed to match the expected value with the retrieved value by the device driver. Especially for older device driver it is needed to specify the allowed value range of the device. For instance:
Measure
This setting will determine when the measurement will be performed during the test. One or more of the available options can be selected.
![]() |
RadiMation will perform the measurement of the configured monitoring input channel before the start of the dwell-time, just before the selected modulation is being activated. |
![]() |
RadiMation will perform the measurement of the configured monitoring input channel during the dwell-time. |
![]() |
RadiMation will perform the measurement of the configured monitoring input channel after the dwell-time has ended, and the selected modulation has been turned off. |
Range
![]() |
This will show a graph line of the specified minimum in the graph and table. |
![]() |
This will show a graph line of the specified maximum in the graph and table. |