DeviceDriverConfigurableAntennaTowerTab

From RadiWiki
Jump to navigation Jump to search

ConfigurableAntennaTowerTab.png

Initialisation and Check

ScreenElementDescription.svg Reset The reset code that needs to be send to device. When left blank, no command will be send.
ScreenElementDescription.svg Init The command that is send to initialize the configured device. When left blank no command will be send.
ScreenElementDescription.svg Get Id The command that is send to retrieve the ID of the device. This is used to check if the device is connected. A commonly used SCPI command is: *IDN?. When left blank, no command will be send.
ScreenElementDescription.svg Returned ID The identifier is used to check if the correct device driver is selected and the device is connected. Leaving this blank, will skip the device check.
ScreenElementDescription.svg Deinit Specifies the command that is send when the device is no longer controlled. This can for example be used to put the measurement device is an intrinsic safe state. Leaving this blank, will keep the device in its last state after controlling it.
ScreenElementDescription.svg Wait for Completion after sending command The checkmark can be enabled so RadiMation® will wait for all the commands to complete, before it continues. This is done by sending SCPI command *OPC? to the device.


Antenna Tower

ScreenElementDescription.svg Stop Movement The command that is send to stop the antenna tower. When left blank, no command will be send.
ScreenElementDescription.svg Current Height The command that is send to request the current height. When left blank no command will be send.
ScreenElementDescription.svg Current Height Format The format (regular expression) to parse the response from the "Current Height" request, and also the unit in Meter, Centimeter or Millimeter should be specified for the response
ScreenElementDescription.svg Go to Height The command that is send to move the antenna tower to a certain height. The command must include a keyword, __meter__, __centimeter__ or __millimeter__ which will be replaced with the corresponding height for the antenna tower. When left blank, no command will be sent.
ScreenElementDescription.svg Position stopped The command that is send to request the status if the antenna tower is moving. When left blank, no command will be send.
ScreenElementDescription.svg Position stopped format The format (regular expression) which will be matched against the response of the "Position stopped" command, when the result is matching the response the tower is stopped.
ScreenElementDescription.svg Current Polarization The command to request the current polarisation. When left blank, no command will be sent.
ScreenElementDescription.svg Horizontal Polarization format The format (regular expression) which will be matched against the response of the "Current Polarization" command. When the result is matching the driver reports Horizontal back to RadiMation.
ScreenElementDescription.svg Vertical Polarization format The format (regular expression) which will be matched against the response of the "Current Polarization" command. When the result is matching the driver reports Vertical back to RadiMation.
ScreenElementDescription.svg Hor. Polarization The command that is send to change the polarization to horizontal. When left blank, no command will be send.
ScreenElementDescription.svg Vert. Polarization The command that is send to change the polarization to vertical. When left blank, no command will be send.
ScreenElementDescription.svg Pol Hor. stopped The command that is send after the command "Hor. Polarization" is sent, with a delay of "Waiting time" between the two commands. When left blank, no command will be send.
ScreenElementDescription.svg Pol Vert. stopped The command that is send after the command "Vert. Polarization" is sent, with a delay of "Waiting time" between the two commands. When left blank, no command will be send.
ScreenElementDescription.svg Waiting time The wait time between the Polarization command and Polarization stopped command.