RadiSense2000DeviceDriverConfiguration

From RadiWiki
Revision as of 08:52, 22 May 2024 by Joro (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Information.png
Note: This page is used to show the configuration of the Raditeq RadiSense 20xx device drivers. This page can now easily be embedded on all relevant device driver pages.

GPIB DeviceStream Configuration.png

On the Communication tab, the desired communication method can be selected and configured. Depending on the selected method, additional relevant settings are shown and can be configured.


ScreenElementDescription.svg Communication Streams Selects the medium or method that should be used to communicate with the device. Depending on the capabilities of the device this can be one or more of:

See the Communication Settings in Chapter 15, on how to configure each of these methods.


DeviceDriverRadiCentreTab.png

There are several methods in which the RadiSense2000DeviceDriverConfiguration can be connected to the PC. The RadiSense2000DeviceDriverConfiguration can for example be connected directly to the PC, or through a plugincard in a RadiCentre 1 or a multi-slot RadiCentre. More information on how to use the RadiCentre is present in the product manual of the RadiCentre. The settings on the RadiCentre tab can be used to specify how the RadiSense2000DeviceDriverConfiguration is connected.

When the RadiSense2000DeviceDriverConfiguration is connected to a multi-slot RadiCentre, also the slot number in which the plugincard is fitted, should be specified.


ScreenElementDescription.svg Directly to PC Specifies that the RadiSense2000DeviceDriverConfiguration is connected directly to the PC, without the use of a RadiCentre.
ScreenElementDescription.svg RadiCentre 1 Specifies that the RadiSense2000DeviceDriverConfiguration is connected to a plugincard that is fitted in a RadiCentre 1.
ScreenElementDescription.svg RadiCentre multi-slot Specifies that the RadiSense2000DeviceDriverConfiguration is connected to a plugincard that is fitted in a multi-slot RadiCentre that also can be manually controlled using the display on the front of the RadiCentre. The slot number in which the plugin card is mounted can also be selected.
ScreenElementDescription.svg RadiCentre multi-slot Ultra Specifies that the RadiSense2000DeviceDriverConfiguration is connected to a plugincard that is fitted in a multi-slot RadiCentre Ultra. This RadiCentre Ultra has no display, and can only be used when remote controlled.


The settings on this RadiCentre tab, only specifies if and which RadiCentre is used. The communication settings on the Communication tab specify the connection settings to communication with the measurement device.

The configuration on the Communication tab should be configured depending on the outgoing connection from the PC. Thus if Directly to PC is selected, the communication settings should be configured as what is actually used between the PC and the RadiSense2000DeviceDriverConfiguration itself. If RadiCentre 1, RadiCentre multi-slot or RadiCentre multi-slot Ultra is selected, the communication settings should be configured as what is actually used between the PC and the RadiCentre. In the configuration where a RadiPower is connected with USB to a multi-slot RadiCentre, which is connected by GPIB to the PC, the communication settings of the RadiPower device driver should thus be GPIB.

If the RadiSense2000DeviceDriverConfiguration is for example connected to slot 3 of a multi-slot RadiCentre which has IP address 192.168.178.95 and is connected by LAN to the PC, the following settings should be configured in the device driver of the RadiSense2000DeviceDriverConfiguration:

  • RadiCentre tab
    • Connection type: RadiCentre multi-slot, using as slot number: 3
  • Communication tab
    • Communication Stream: VISA
    • LAN: 192.168.178.95

DeviceDriverSoftwareUpdateTab.png

The Software update tab can be used to update the software of the RadiSense2000DeviceDriverConfiguration.

ScreenElementDescription.svg Software Specifies the filename of the software update file that should be used to update the software of the measurement device.
ScreenElementDescription.svg Browse Allows to select the software update file.
ScreenElementDescription.svg Update software Starts the actual software update. First some checks are performed, and if those checks are successful, the actual software update is performed.
ScreenElementDescription.svg Status Shows a message during the software update, indicating the performed action and the actual status.
Warning-48px.png
Warning: The software update can take a few minutes. During the actual software update the window is disabled, and cannot be closed. It is possible that Microsoft Windows shows messages that the RadiMation® software is not responding. Ignore those messages and do not kill, abort or end the software. Also do not disconnect the connection between the RadiSense2000DeviceDriverConfiguration and the PC, while the software update is being performed.

After the software update is completed, a messagebox will be shown that the software update has been completed succesfully. In the case that an error has occured, this will also be shown. In case that an error has been detected, it is strongly suggested to directly use the RadiMation® Error Report function to report the error to Raditeq.

DeviceDriverRadiSense2000Tab.png

The RadiSense tab can be used to configure the specific settings of the RadiSense2000DeviceDriverConfiguration.

ScreenElementDescription.svg Direction If the field strength of a specific single axis or an isotropic value should be measured.
ScreenElementDescription.svg Filter Setting The filter that should be used during the measurements.


DeviceDriverRadiSenseUserCalibrationTab.png

The User Calibration tab can be used to upload the data of an user calibration into the RadiSense2000DeviceDriverConfiguration. This calibration data can be used by the probe internally to to correct the measured values.

ScreenElementDescription.svg Use calibration correction if available If this option is activated, and if a user calibration is stored in the probe, then the correction will be used by the probe itself, to internally correct the measured value with the user calibration data. If this option is off, no correction of the measured values will be done.
ScreenElementDescription.svg Browse Allows to select the correction file that contains the User Calibration data of the RadiSense2000DeviceDriverConfiguration.
ScreenElementDescription.svg Program calibration table Starts the actual uploading of the calibration table. First some checks are performed, and if those checks are successful, the actual uploading is performed.
Report generator.png
For more information on how to program the RadiSense 10 calibration table, see https://wiki.radimation.com/wiki/index.php/RadiMation_Application_Note_135