Release Notes/Solved items Version 5.7.2

From RadiWiki
Revision as of 14:23, 10 May 2010 by Jewe (talk | contribs) (Created page with '== RadiMation version 5.7.2 == * #2204: Add a peak by clicking on the emission graph * #2920: disable zoom in does not work directly * #3073: Trace gaps on emission plots * #…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

RadiMation version 5.7.2[edit]

  • #2204: Add a peak by clicking on the emission graph
  • #2920: disable zoom in does not work directly
  • #3073: Trace gaps on emission plots
  • #3497: Keithley 2000 scanner does not detect connected device correctly
  • #3502: RadiMation stays in a never ending loop to zoom the peak
  • #3565: Negative turntable angles should be allowed in combination with the "measure during turn" option
  • #3584: Wrong value readout of LeCroy 9361 scope
  • #3628: Overloaded driver of the ESU is crashing then the device *IDN? description is not in capitals
  • #3629: Changing the test order before reporting is crashing the RadiMation
  • #3630: Driver: Maturo NCD
  • #3634: Scaling in CE multiband is going to -1000 during the test.
  • #3639: Driver: AH system SAS-570
  • #3640: Driver: AH system SAS-571
  • #3642: Driver: AH system SAS-550-1B
  • #3643: Driver: AH system SAS-560
  • #3649: Driver: HP 8673E
  • #3650: Driver: HP 8662A
  • #3654: Driver: IFI SMCC10
  • #3655: Driver: OPHIR 5163
  • #3657: Driver: HP 8341B
  • #3658: Driver: Solar 6338-5-PJ-50N
  • #3659: Driver: Solar 9233-50TS-50N
  • #3661: Driver: Solar 7334-1
  • #3662: Driver: Electro metrics EM-6892
  • #3663: Driver: Electro metrics EM-6960
  • #3664: Driver: Electro metrics EM-6961
  • #3665: Driver: Electro metrics EM-6876
  • #3668: Driver: Solar 9251-1
  • #3673: Peak selection is not working as expected after deselecting all the peaks
  • #3675: Configuration for optimize angle and height has problems with the measure- and observation time of different detectors
  • #3676: During Optimize Height actual defined settings are not used but settings defined a step before
  • #3677: When you press <<Detect Peaks>> after a radiated emission test in multiband you can not select more than one peak afterwards.
  • #3678: Peak detected in first band but not in second band
  • #3680: Configurable device signal generator device driver is not taking the correct codes in version 5.6.9
  • #3682: Emission multiband is slow when 200 peak sweeps are used
  • #3692: Prana amplifier does not turn off when the amplifier is changed during manual mode