RadiMation version 2013.1.15[edit]
- #1680: The resolution for the reflection coefficient should be increased from 0.001 to 0.0001
- #2232: Device driver to control the R&S ESI(B) series analyzers/receivers over LAN
- #2758: ZVK measuring times are not inserted in side the machine, it is always 1 sec.
- #4041: Antenna mast Frankonia FC 02 not working
- #4324: Error Advantest TR4172 not all bytes are written to the GPIB
- #4464: Driver: tracking generator R&S ESPI3 receiver with option FSP-B9
- #4554: R&S ESPI7 ethernet communication
- #4658: Network analyzer measurement: Swap noise and full through measurement
- #4659: Network analyzer measurement: Support Full 1 port measurment, which only measures a single port
- #4687: Strange graphs are included in the report if the frequency has been changed to an already tested frequency in RI Single band manual mode
- #4689: Emco 2090 is controlled with an offset
- #4804: Simultaneously remote control LISN ESH3-Z and use Spectrum Analyser of R&S ESAI/ESMI doesn't work
- #4904: No graphical display of results and no results are stored
- #4911: Help Technical Support items are not working
- #4912: Advantest TR4172 is not using Video Average detector
- #4913: Wrong dates are shown in the EUT window
- #4915: Antenna tower limits are not retained for the EMCO2090
- #4917: Driver: R&S ZNB 40 Network analyzer
- #4918: RadiSense 4.51 probe is not correctly detected
- #4920: Configuration of magnetic field substitution test level is problematic
- #4921: Unhandled exception after finishing RI substitution tests
- #4922: SMA100A not working correctly
- #4925: Powermeter measurement with the R&S FSP below 300 Hz measures the zero feed through signal
- #4927: Driver: pre-amplifier Teseq LNA 6901
- #4928: Driver: pre-amplifier R&S AFS
- #4931: Driver: Injection device Mess Electr NNBM8125
- #4937: StandardDetails window is not automatically resizing
- #4939: Default Address Information screen text is cut off
- #4946: Text in Calibration Import window not completely visible
- #4949: Does RadiMation support time domain scan
- #4951: Is it possible to use a calibration file at 20vm to generate a field of 3vm
- #4956: How can we run 5.8.38 and 2013.1.15 on the same PC
- #4957: Files generated in 2013.1.15 are not readabel in 5.8.38
- #4961: How to add attenuators for calibration
- #4971: How and with which RM version can we control the power meter RPR3006P?
- #4980: The 'number of sweeps' setting in a network analyzer test is not working