Release Notes/Solved items Version 2017.1

From RadiWiki
Revision as of 11:21, 21 December 2017 by Joro (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

RadiMation version 2017.1.7[edit]

  • #6971: Driver: LeCroy WaveSurfer and Wave Runner oscilloscope series
  • #8538: Driver: CPI Amplifier J-series
  • #8541: Option to enable/disable frequency correction of PMM EP600-series
  • #8553: Support Mode 4 of the RadiPower
  • #8555: ErrorReport: "Collection was modified; enumeration operation may not execute. "
  • #8565: Driver: Steatite atennas
  • #8566: Driver: Flann Microwave antennas
  • #8569: Use Internal 10 MHz out for IFR 2023 Reference clock
  • #8582: Support the Preamplifier of the new TDEMI X
  • #8623: line coupling is only showing 1 line coupling in VDI TSF configuration
  • #8662: Object reference error while using minimum performance in a MB magnetic field closed loop method test
  • #8685: AD Channel colors are the same
  • #8689: Note field cannot be larger then 1000 characters.

RadiMation version 2017.1.6[edit]

  • #4969: CANoe interface object not initialized correctly
  • #7496: Sentinel dongle failure
  • #7586: Not possible to export attached pictures in the report by using the Report Generator
  • #7696: Graph is not showing (correct) trace data during CI calibration and RI Multiband
  • #7829: Implement the AnalyserAsPowerMeterDecorator for ESU and ESI series powermeter device drivers
  • #8062: Outside Points
  • #8068: Marconi 2042: Specific System Error: 2
  • #8165: Ability to use AM modulation with the obsolete Agilent Technologies E4432B Signal Generator
  • #8287: Extend R&S ESCI driver to allow selection of CISPR-Average or (old-)Average as Average detector
  • #8340: Ability of 'Power Measurement' settings for the R&S ESR7 to avoid unexpected bandwidth jump behavior
  • #8378: Enabled Calibration before final measurements option causes GPIB: EABO timeout
  • #8384: External reference setting of the R&S ZNB is changed during initialization
  • #8403: Rotate to position after end of test (de-initialization)
  • #8412: Ability of 'Power Measurement' settings for the R&S ESU40
  • #8429: Opening of a very large CI Multiband test is very slow
  • #8431: Unclear description when the RadiSense is still in standby
  • #8444: Driver: BiDirectional Coupler BDC 0660-30/100
  • #8446: Driver: Teseq CBA 1G-150 amplifier
  • #8450: ESPC Not all bytes are written to the GPIB board "Perform short calibration before final measurement" option
  • #8452: IFR 2052 driver is not working correctly
  • #8467: RI Multiband AM modulation is only used for first point, after that its none if modulation conservation is activated
  • #8477: RadiLog Error Report does not make screenshot from external monitor
  • #8479: Maturo MCU raises a Lock error during deinitialization
  • #8481: Driver: RSSA3021X Spectrum analyser
  • #8483: R&S ESIB40: Function not available;FREQ:STOP:LINK START
  • #8488: N9038A: System Error: -410: Query Interrupted
  • #8493: CARAD software invalid messages received
  • #8503: Marked peaks are not saved
  • #8504: Minimum power of CI Fixed power test is -40 dBm
  • #8508: Ability to select Internal or External reference clock on some devices
  • #8510: Changing unit causes crash
  • #8511: Frequency correction of PMM EP603
  • #8512: Device Driver: Marconi 2052
  • #8518: Not possible to generate a printout of the amplifier linearity test results
  • #8523: Compression test table: uses wrong unit in time and frequency column
  • #8526: Generated power of CWS500N1 drops at 350 kHz
  • #8527: RSSML Merge reference source
  • #8556: Negative power reading of NRP-Zxx powermeter
  • #8557: Wrong de-initialisation NRP-Zxx
  • #8573: Driver Antenna Schaffner Bilog
  • #8584: Driver: PMM EP604
  • #8602: Driver: Multimeter Agilent 34401A AC and DC measurement
  • #8603: Driver: generic configurable coupler for the couplers of ATM Microwave
  • #8604: Driver: generic configurable coupler for the couplers of RF Lambda

RadiMation version 2017.1.5[edit]

  • #7633: Unexpected oscilloscope measurement value of first frequency point
  • #7652: Configurable Injection Device custom frequency range is not retained
  • #7689: Graph export is showing unexpected end frequency
  • #7901: ControllerDelay for a GPIB controlled Maturo MCU can be 0
  • #8092: When a printout is generated and printed the 'busy' dialog should be shown, to indicate that the PC is busy
  • #8113: Unable to communicate with CWS500N 1.2
  • #8233: RadiMate slow measurement speed
  • #8247: Tektronix Oscilloscope returns No data or incorrect data was returned by the device
  • #8334: No measurement data during "Continuous Measurement" as altitude scan using CO3000 controller
  • #8384: External reference setting of the R&S ZNB is changed during initialization
  • #8406: Password of a new engineer is unknown, and cannot be changed
  • #8408: EUT Monitoring channel Maximum and Minimum Limits are not shown
  • #8418: Maturo NCD over lan
  • #8419: Settings in 'Fixed step count' frequency step setting in a multiband immunity test is not remembered
  • #8420: Fixed step count as step frequency in multiband immunity is not working when 'per octave' is selected
  • #8421: Agilent E4422B unable to connect
  • #8422: Singleband GTEM emission data is not shown when a dot is used a decimal symbol
  • #8423: HP 34401: Timeout while waiting for *OPC command
  • #8425: VDI duplicate band Object reference
  • #8430: Internal AM modulation on the Agilent E4422B is not supported
  • #8433: Exporting of graph data to CSV is not always in Excel compatible format
  • #8435: Allow control of CANoe 9.0.65 (SP2)
  • #8436: Also notify the CANoe CAPL interface of dwelltime start and dwelltime end
  • #8437: Possibility to leave CANoe running when the CANoe switch matrix is used
  • #8441: Changing polarization of Frankonia FC02 raises 'Illegal parameter value' error
  • #8448: Destination array was not long enough. Check destIndex and length, and the array's lower bounds.
  • #8451: CWS500N Checksum error
  • #8455: Black lines in RI tests
  • #8456: Conducted RF immunity stepsize 0,5 per cent not possible
  • #8461: Preselection filter before the test
  • #8464: Changing region settings causes data loss.
  • #8469: Agilent Technologies E4422B: "Undefined header" when turning off AM modulation
  • #8475: When changing step frequency of 1 band, all the bands step sizes change.
  • #8476: R&S ESI: Function not available: INP:GAIN:STAT OFF, when FFT filter is used
  • #8485: Changing test level settings after its loaded by TSF, is not using last setted device.
  • #8486: Export EUT filename shows TSF filename
  • #8515: Driver: emtest esd NX30
  • #8519: Missing NIPALU.DLL error when starting RadiMation
  • #8536: Merge test blank page

RadiMation version 2017.1.4[edit]

  • #6093: Turntable CO3000 is not moving when setting it to make a full turn from 0 till 360 degrees
  • #6798: Apply multiple testlevels at same frequency
  • #7780: Exporting EUT executed tests list
  • #8207: Configurable Device driver frequencies with different units
  • #8244: Climat typo it should be Climate
  • #8301: Unhandled exception access to the path ErrorModeFile.radilog is denied
  • #8322: RPR2006C overranges during CDN voltage calibration
  • #8371: 1% Stepsize in RI Manual mode is not correct when a frequency list is used
  • #8382: ODBC customer database is not working anymore
  • #8383: Store RADIMAT_SESSION.LOG in a PC local temporary folder
  • #8389: Received power is rounded in Antenna Scan EUT Calibration
  • #8397: Searching for a customer in the customer database closes the window before the customer can be selected
  • #8399: Loading a multiband immunity test is not possible, unable to create VSWRGatherer
  • #8415: RadiMation crash at startup after updating to 2017.1.4
  • #8416: Agilent N9000A (version A.07.06) Error with GPIB
  • #8426: Unable to select correct OPC channels for AD converter.
  • #8435: Allow control of CANoe 9.0.65 (SP2)
  • #8443: Driver: Amplifier BLMA 1060-50
  • #8458: Unable to connect to radigen RADIGEN0230A

RadiMation version 2017.1.3[edit]

  • #8210: Opening a RE Multiband test is taking one and a half minutes

RadiMation version 2017.1.2[edit]

  • #8045: RDC files are always stored to the Global configuration path while standalone setting is used
  • #8091: Improve calculation of multiband immunity graphs
  • #8097: Linear and logaritmische scale setting are not saved
  • #8145: Unable to show AD Channels in 2017.1.1
  • #8199: Opening Multiband Immunity results takes a lot of time since graph filtering is implemented
  • #8238: Language file 0.lng
  • #8363: RadiLog option in view menu incorrect behaviour

RadiMation version 2017.1.1[edit]

  • #506: 1 Hz on off modulation is not possible according to the DO-160E / ED-14E standards
  • #2947: Amplifier is turned off when closing another multiband test
  • #3032: Opening an Multiband test while performing a Multi band test is messing up the test
  • #3241: RI multi band test is overwriting the previous information
  • #3598: Configurable Peak Table
  • #3970: Radiated emission multiband: detector from pre-measurement used during "continuous measure"
  • #4001: Difficulties to differ results from 2 bands with the same frequency range in multiband immunity tests
  • #4159: RBW in peak table (RE multiband)
  • #4248: Error Multiband start and end frequency
  • #5189: Sweeptime is used during final measurement instead of the QP measurement time
  • #5216: Test started event log entry should only be added in a restarted multiband test if manual or automatic is pushed
  • #5307: Despite of no changes the message "The file has changed, do you want to save changes?" is shown
  • #5341: After a Manual Mode change there is undesirable regulation
  • #5440: Can't zoom out after maximum zoom in at graph
  • #5469: Invalid Device Driver Handle error (Kalmus 727LC)
  • #5529: Invalid Device Driver Handle (Virtual) Amplifier
  • #5545: Graph is not updated when switching to the second band
  • #6075: During instable measurements it may happen that Peak and Quasi-Peak measurements are inconsistent
  • #6191: Add an 'Add Test' button to the Sequence window, to simplify the addition of a test
  • #6230: Table export only copies the time and frequency data
  • #6264: Overlapping bands in MB immunity are tested multiple times when only the modulation is different
  • #6352: Changing the activated detector during Continuous Measure clears the measured value of the deactivated detector
  • #6449: Frequency range settings are generating an error and the configuration of the TSF is lost when a read only test is saved as new test
  • #6452: Frequency array calculation of emission sweep of analyser is missing a step
  • #6861: Radiated Immunity Multiband is referring to a receiver
  • #6907: Improve autosave functionality that it no longer overwrites the current test data, but first makes a backup
  • #7074: Possibility to change polarization of an existing calibration file
  • #7077: continuous measure is using sweep time setting
  • #7143: RI Multiband only shows Puls when AM is also selected
  • #7147: Redoing an already performed test overwrites the previous test-results
  • #7167: Amplifier linearity measurement accepted power lines hidden
  • #7177: Unable to zoom graph while test is running
  • #7203: A generic error occurred in GDI+
  • #7214: PI windows still do not fit at full window size using an acceptable resolution
  • #7242: Two electrical field graphs are shown. Which one is correct?
  • #7247: Prana amplifier is not correctly being put in Operate during immunity test
  • #7249: Show example of unit settings
  • #7252: RadiMation Free Responsiveness
  • #7254: Change Basic small controlling window for PowerMeter
  • #7255: Change Basic small controlling window for Amplifier
  • #7365: Minimum size of 'Burst' and 'Envelope Tracing' tabs of the VI Powermeter
  • #7411: Connection state is still orange while the device is already connected
  • #7441: Minimum Form Size is always set to 0,0 at runtime
  • #7449: VI Powermeter error lock when removing device
  • #7499: RadiMation opening EUT is slow
  • #7523: PI EFT Test levels are not covering all the different measurements
  • #7575: RadiLog long tests multiple log files.
  • #7581: Test description of the test is not visible in the test data
  • #7637: Driver: emtest UCS500-M4
  • #7644: Filling the EUT information is being slow.
  • #7717: Unchanged LLF is asking to be saved when closing the window.
  • #7721: System attenuation gain duplicate measurements
  • #7737: Report generator query keyword for the table information is not exporting any data
  • #7760: Ability to merge multiple Radiated Immunity CALibration files for different frequency ranges into one
  • #7768: Wrong frequency at monitoring input events
  • #7769: Saving tsf as ReadOnly data lost
  • #7773: Incorrect table information for frmVIPowerMeter at the ctlControlGraph table
  • #7779: Overlapping bands in MB immunity are tested multiple times when only the modulation is different
  • #7796: Compression Gain System Calibration default 1 amount of samples seems to result in a corrupt calibration file
  • #7799: Sorting of the ctlFormattableGrid is different when new columns is added
  • #7811: Clear button on the VI Fieldsensor doesn't seem to work when the table is shown
  • #7812: VI Fieldsensor keeps raising error messages when the probe is turned off before it is disconnected
  • #7819: No data document could be created for the test identifier: "
  • #7820: Test specific templates are gone after graph customization
  • #7824: Reflected power input in Multiband Immunity
  • #7836: Connect button is not showing 'Connecting'
  • #7842: Saving EUT file with keywords
  • #7844: Incorrectly saved Test results starts the test when reviewing the Test results
  • #7845: PI test EUT cable selection should be changable while TSF is read only.
  • #7866: Corrupt file saving when validator failed.
  • #7867: Out of memory when starting RI test
  • #7878: RadiLog error report containing # in description gives error.
  • #7885: Test data like notes and specific templates settings are updating or overwriting EUT overview settings
  • #7886: Resizing of the Graph customization window hides some graph customization controls
  • #7887: Missing keyword in Table shifts the table
  • #7893: Data file is not saved every 5 minutes, when a final peakmeasurement is busy
  • #7894: Radilog memory is not being swapped
  • #7896: Missing last test frequency in ReportGenerator output
  • #7897: Error Report send not always sending
  • #7898: & sign in device driver name is not correctly shown in the EUT Monitoring dialog
  • #7902: MessageBox that is shown from the testsite before actions can be shown behind the main window
  • #7903: Unable to start RadiMation with incorrectly configured path
  • #7904: Default table settings are stored in the user interface
  • #7905: ReportGenerator Report and output file selection is not saved.
  • #7908: Invalid tsf in sequence can corrupt the sequence
  • #7915: Merging of calibration files looses the originally desired fieldstrength
  • #7918: Graph customization window can be made too small
  • #7922: External modulation should not be possible for a VI signal generator
  • #7926: The RBW value has changed by the device from 120 to 100 User description:
  • #7927: Duplicate more than 1 test at the same time in the new Sequence window.
  • #7932: Very long filenames of the RadiLog file cannot be opened by RadiLog
  • #7937: Signal generator VI frequency can be set outside the range of the controlled device
  • #7940: Why is the Peak Table disabled during an Emission test?
  • #7946: Opening test results directly sets the changed flag.
  • #7947: Switching to a different band using 'Continue automatic mode settings' is incorrectly checking if the carrier frequency is valid
  • #7950: Ability to hide Report Generator Template column for 'The keyword "" is available in the tempate' window
  • #7951: Sending unprintable characters with configurable device driver
  • #7953: Frequency list settings are not saved for a sequence and thus not used when Fixed power test is run from within a SEQ file
  • #7955: Size of Voltage Dips and interrupts TSF window can be made too small
  • #7962: RadiLog to long subject gives error. Strange behaviour occurs.
  • #7963: RadiLog parsing fail
  • #7964: Directly after installation, the power graphlines are not shown in the VI Powermeter
  • #7965: A read only TSF is also asked to save the changes
  • #7966: Last View update is being skipped
  • #7969: EFT tests with repetition rate 100 kHz (burst duration 0,75ms) can NOT be performed
  • #7971: Radilog saving file, file in use while reporting error.
  • #7980: Test data files are zero based count on disk which is confusing for end-users
  • #8003: Clear graph button for VI windows does not work (when disconnected)
  • #8004: Opening of locked files should wait for a few seconds and retry opening locked files
  • #8009: Opening a second CE Absorbing clamp test, switches both graphs from log to linear xaxis.
  • #8011: Exporting polar graphs contains a white space area.
  • #8015: Improve graphical representations of graph
  • #8021: When a Band has been selected the TSF is marked as being changed
  • #8029: Graphs during Multiband Immunity are not updated during test
  • #8030: VI powermeter windows does not work correctly
  • #8033: Combine user defined units to prevent multiple equal axis from being shown in graph
  • #8040: Error window location cut off
  • #8046: Error report, cant write to temporary directory
  • #8053: EUT being removed after network reset.
  • #8054: Manual frequency is not measured when it is exactly the same as the last frequency in the calibration file.
  • #8061: Before actions are prompted multiple times at the end of the test
  • #8069: Shortcutkeys not updating ctlEvents
  • #8085: Gaps in graph lines.
  • #8096: Auto detect peaks shows object reference error
  • #8101: RadiLog SQL files containing ";" is not opening correctly
  • #8104: RadiMation does not automatically refer and open the latest installed version
  • #8106: RadiLog object reference after saving
  • #8107: Errors are not reported in RadiMation
  • #8108: Error window tooltip causes object reference error.
  • #8109: Export full PEAK table
  • #8112: Radilog Parsing error when opening log from zip
  • #8114: Calibration Files do not use the same calibration method
  • #8130: Virtual Instruments infinit loop errors
  • #8137: Language files as unicode
  • #8138: VDI Impedance is set incorrectly to the device
  • #8140: VI Signal Generator all controls are still disabled after connected
  • #8144: Exporting graph to LLF in the graph options crashes