RadiMation Application Note 104

From RadiWiki
Revision as of 10:16, 29 January 2019 by Joro (talk | contribs) (How to determine the current sensor transfer impedance)
Jump to: navigation, search

How to determine the current sensor transfer impedance

The transfer impedance of a current sensor is important and required to perform accurate current measurements. A typical current sensor transfer impedance can be retrieved form the manufacturer of the current sensor, or it can be determined in a calibration laboratory. It is however also possible to determine the transfer impedance of a current sensor yourself, if you have the correct equipment.

This Application Note explains how measurements can be done in RadiMation® to determine the transfer impedance of a current sensor. These measurements are done by using the Attenuation/Gain calibrations as they are provided by RadiMation®. After the Attenuation/Gain calibration is performed, some calculations are needed to determine the correct transfer impedance, however these can easily be done in Microsoft Excel. A verification of the calibration and recalculation of the data can be done to ensure that the expected current is indeed correctly measured by RadiMation®.

Performing the Attenuation/Gain system calibration

Performing the Attenuation/Gain EUT calibration

Converting the determined to a transfer impedance

Specifying the transfer impedance for the current sensor device driver

Verification

After the transfer impedance of the current sensor is determined and attached, it is also possible to verify if RadiMation® is able to measure the expected current.