Talk:RadiMation Application Note 111

From RadiWiki
Revision as of 15:20, 25 March 2019 by Tjsc (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Short description of the application note:

Hardware setup

  • Include a graphical drawing of the radicentre in a setup:
    • with the interlock connected to the door of the anechoic chamber
    • Signal generator to the Normally Open connector of the First Relay of a switch card and then going to the amplifier
  • Photograph of the back of the radicentre showing the relais and the interlock connector
  • Technical information of the interlock connector on the radicentre
  • Remark that the laser will turn off

Software configuration

  • RadiCentre® Switch matrix device driver (to get confirmation/feedback of the open interlock in RadiMation).

Review Status

JORO: Not yet reviewed. Joro (talk) 13:15, 31 January 2019 (CET)


TJSC Reviewed. Joro (talk) 16:13, 25 March 2019 (CET)

  • Made a couple of grammatical changes.
  • Drawing can be a little more clear, As it looks now it looks like the circuit is never closed which is strange and not what you would expect. See other remarks above for tips to refine the picture.
  • I would add a extra caption in the end for a conclusion. I would be nice to describe the process one last time. This wa you also realy understand what is happening when which step is initiated in the software For example:

We have now set up ......... Now when we start a test the relay will switch to .... This will place the interlok in the path and when it is disconnected it will stop the test. When the test stops the relay will switch back to "State"