Release Notes/Solved items Version 5.1.6

From RadiWiki
Revision as of 09:01, 3 January 2020 by Madero17 (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

RadiMation version 5.1.6[edit]

  • #1978: Chinese language translation added
  • #1976: Correction of current probe device in second band is not correctly selected
  • #1975: Graph lines in multiband test, are always using the calibration file that is specified in the first band
  • #1972: Used calibration file data is not stored in test results of a multiband immunity test
  • #1970: ESPI/ESCI as powermeter is giving error when selecting input 1
  • #1967: Analyser read out of HP4395A crashes, problems with determining the correct data format (IEEE 32 bit floating point)
  • #1966: Multiband Immunity tests are using 0 Hz carrier frequency in the begin of the test
  • #1964: Multiband immunity test is always requiring a coupler. Also if only signal power is used
  • #1963: Description of Radimation Error number 13005 cannot be found: Coupler could not be found!
  • #1955: Review of manual data in Network Analyser EUT calibration test, crashes software
  • #1952: Unclear error when frequency of multiband test is out of frequency range of calibration file
  • #1546: Multiband for immunity testing
  • #626: Samenvoegen van verschillende frequentie gebieden in een TSF is niet mogelijk