RadiMation Application Note 157
How to perform a MIL-STD-461 RS103, radiated susceptibility, electric field[edit]
This application note explains how the MIL-STD-461 RS103, radiated susceptibility, electric field test can be performed with RadiMation®
The exact requirements and test methods for the RS103 are specified in the MIL-STD-461.
Necessary equipment[edit]
The following devices are necessary to perform the CS109 test:
- Signal generator
- Amplifier
- Antenna
- Field probe
Define the test level[edit]
Create a correction file for the test level[edit]
-
File
-
New
-
Correction
-
-
-
First create a correction file in RadiMation® and specify the test level (See 'Table XI RS103 limits.').
-
File
-
Save correction
-
-
Store the test level as correction file on disk.
This correction file with the test level will be used during EUT testing.
EUT Testing[edit]
EUT Testing equipment[edit]
The configuration of the eut test site should contain the following devices:
# | Device name | Tab in testsite configuration window | note |
---|---|---|---|
Signal Generator | Devices 1 | The signal generator to use | |
Amplifier | Devices 1 | The amplifier to use | |
Field Sensor 1 | Field probes | The field sensor to use |
Configure the EUT test[edit]
To perform the test on the EUT, create a radiated immunity multiband test. The radiated immunity multiband test, can be started by selecting from the menu:
-
Tests
-
Radiated Immunity
-
Multiband
-
-
-
![]() |
The start frequency of the test. For example 2 MHz. |
![]() |
The stop frequency of the test. For example 30 MHz. |
![]() |
The frequency step, see Table III. |
![]() |
The dwell time. |
![]() |
Constant. |
![]() |
The modulation to use see below. |
![]() |
The equipment needed for the radiated susceptibility test. |
![]() |
Injection clamp. |
![]() |
Specify the Electrical field closed loop method test level. Also configured a "Variable field" |
![]() |
No inputs are needed. |
At TestLevel click Add to add a new Test level and select TestLevel - Electrical field closed loop method
![]() |
The description of the test level. |
![]() |
Variable field, and specify the correction file for the applicable test level. When the level is one value this value can be specified with Constant field |
![]() |
Specify the tolerance to use. |
![]() |
Check Probe 1 to measure with the first probe. |
When all settings are configured press Start Test to run the test.