{{RadiMation}} has an build in Amplifier protection that will limit the power of the controlled signal generator.  
 
{{RadiMation}} has an build in Amplifier protection that will limit the power of the controlled signal generator.  
By default, the signal power is limited 0dBm to the amplifier input.
+
By default, the signal power is limited 0dBm to the amplifier input.
By default, the signal power can also not exeed 20dBm.
+
By default, the signal power can also not exeed 20dBm.
  
  
Line 14: Line 14:
 
[[File:CorrectionFile.png|600px]]
 
[[File:CorrectionFile.png|600px]]
  
A new correction file can be created that only contains the column "Correction". Then this correction should be applied to the maximum frequency range of 1 Hz to 120GHz.
 
  
The correction can then be added to the Amplifier protection files.
+
A new correction file can be created that only contains the column "Correction". Then this correction should be applied to the maximum frequency range of 1 Hz to 120GHz.<br>
If no correction files are specified, the signal power is limited to the 0dBm.
+
The correction can then be added to the Amplifier protection files. If no correction files are specified, the signal power is limited to the 0dBm. <br>
Adding the +40 correction, allows the signal power to go up to +40dBm, and then is limited by the default signal power limit of 20dBm.  
+
Adding the +40 correction, allows the signal power to go up to +40dBm, and then is limited by the default signal power limit of 20dBm.<br>
 +
If adding a correction to the maximum forward and/or maximum reflected , the signal power is limited by the measured forward and/or reflected power.
  
If adding a correction to the maximum forward and/or maximum reflected , the signal power is limited by the measured forward and/or reflected power.
 
  
 
[[File:Amplifier.png|600px|http://wiki.dare.nl/wiki/index.php/Virtual_Amplifier|Virtual Amplifier]]
 
[[File:Amplifier.png|600px|http://wiki.dare.nl/wiki/index.php/Virtual_Amplifier|Virtual Amplifier]]

Revision as of 08:32, 19 April 2018

Amplifier protection

Introduction

RadiMation® has an build in Amplifier protection that will limit the power of the controlled signal generator.

By default, the signal power is limited 0dBm to the amplifier input.
By default, the signal power can also not exeed 20dBm.


Change the Amplifier protection

The protection limit can be overwritten by adding correction to the Amplifier protection files section of the Amplifier device driver.

CorrectionFile.png


A new correction file can be created that only contains the column "Correction". Then this correction should be applied to the maximum frequency range of 1 Hz to 120GHz.
The correction can then be added to the Amplifier protection files. If no correction files are specified, the signal power is limited to the 0dBm.
Adding the +40 correction, allows the signal power to go up to +40dBm, and then is limited by the default signal power limit of 20dBm.
If adding a correction to the maximum forward and/or maximum reflected , the signal power is limited by the measured forward and/or reflected power.


Virtual Amplifier