Line 14: Line 14:
 
When an immunity test is started, all the activated EUT Monitoring inputs will be measured on each test frequency, and thus the data from the CAN bus (through the CANoe software) will also be included in RadiMation.
 
When an immunity test is started, all the activated EUT Monitoring inputs will be measured on each test frequency, and thus the data from the CAN bus (through the CANoe software) will also be included in RadiMation.
  
= Getting information to CANoe =
+
= Supplying RadiMation values to CANoe =
 
Use the CAPL interface to communicate with the software.
 
Use the CAPL interface to communicate with the software.
  

Revision as of 09:29, 15 September 2017

CANoe from Vector is used for reading out the CAN or LIN bus.

It is possible to retrieve measurement values from the CAN bus into RadiMation. And it is also possible to use measurement values from RadiMation in the CANoe software, which allows to put the RadiMation measurement values on the CAN bus. Each of these data transfer directions can be used in a RadiMation immunity test, and it is also possible to use both data transfer directions in the same immunity test.

Retrieving information from CANoe into RadiMation

Use the CANoe Interface AD Convertor device driver to read out measurement values from the CANoe Software into RadiMation.

To connect with RadiMation you need to configure the following things:

  1. Create the CANoe Interface device driver (as an AD Convertor) in RadiMation.
  2. Select the created CANoe Interace device driver as an AD convertor in the testsite that is used during an immunity test.
  3. Configure the EUT Monitoring inputs in RadiMation to measure values from the selected AD Convertor

When an immunity test is started, all the activated EUT Monitoring inputs will be measured on each test frequency, and thus the data from the CAN bus (through the CANoe software) will also be included in RadiMation.

Supplying RadiMation values to CANoe

Use the CAPL interface to communicate with the software.

CAPL

CANoe supports CAPL, a programming interface. Through this interface RadiMation can send information back the CANoe software. For Example:

  • Frequency
  • Field Strength
  • Signal power
  • Forward power
  • Current
  • Turntable angle
  • Antenna height
  • Antenna polarization
  • ... (and more)

RadiMation connects through COM to this application, which requires that the CANoe software should be installed on the same PC.

To connect with RadiMation you need to configure the following things:

  1. Create the CANoe Switch Matrix device driver in RadiMation.
  2. Select the created CANoe Switch Matrix device driver in the testsite that is used during an immunity test.
  3. Include the RadiMationInterface.can file inside your CANoe/CANalyser project. The contents of the RadiMationInterface.can file can be extended to take specific action.

Note that the functions in the RadiMationInterface.can file do not support a callback to the RadiMation application. So this CAPL interface can only be used to have updates of measurement values and settings during a test from RadiMation to CANoe or CANalyser.

Information.png
Note: It is not possible to determine if a CAPL function is existing in the CANoe/CANalyzer COM server.

When the CAPL function is not existing in the RadiMationInterface.can file, the call will go be forward to the CANoe software itself, and there will be no error message or return value.

Events in the CAPL interface

The events given to the CAPL interface are event triggered. This means that the information is send the moment it becomes available.

For example, when the Forward power has been measured the forward power information is send through the interface. The same goes for a frequency change.

This also means that when information is not available, for example the test is done only on signal generator level then the forward power will not be send at all.

Which events are triggered, and how often they are triggered is completely dependent on the configuration of the TSF in RadiMation®.

When filtering of the events is required then this can be implemented in the CANoe software.