Difference between revisions of "Manual/Export Graph From Window"

From RadiWiki
Jump to: navigation, search
Line 1: Line 1:
From RadiMation version 5.1 and up the direct export of graphs has been limited. In previous versions you can specify everything from colours to lines. The main reason for the limitation is that RadiMation is supporting customisation of the graph's by default. This introduces the need to fully control the graphs.  
+
From [[RadiMation]] {{LinkVersion|5.1}} and higher, the direct export of graphs has been limited. In previous versions it was possible to customize several parts from the graph, ranging from to be used colours to specific line types. This kind of customization is not possible anymore. The main reason for the limitation is that RadiMation is now supporting customisation of the graphs by customization windows in RadiMation itself. This introduces the need to fully control the graphs.  
  
 
If there is no limitation the following sequence of actions is possible:
 
If there is no limitation the following sequence of actions is possible:
Line 13: Line 13:
  
  
{{Note|You can still get to the export window of the graph. click the graph with the mouse and press 'x'}}
+
{{Note|It is still possible to access the export window of the graph module itself. Click the graph with the left mouse button and press the 'x' on the keyboard}}
  
{{Note|Graph customisation only applies to Multiband tests}}
+
{{Note|Customization of the graphs is only possible in  Multiband tests}}
  
 
{{Version|5.1}}
 
{{Version|5.1}}

Revision as of 11:57, 29 February 2008

From RadiMation version 5.1 and higher, the direct export of graphs has been limited. In previous versions it was possible to customize several parts from the graph, ranging from to be used colours to specific line types. This kind of customization is not possible anymore. The main reason for the limitation is that RadiMation is now supporting customisation of the graphs by customization windows in RadiMation itself. This introduces the need to fully control the graphs.

If there is no limitation the following sequence of actions is possible:

  1. Test is performed.
  2. Test reviewed.
  3. Graph configuration changed.
  4. Test closed.
  5. Test opened again.

Resulting in a graph that is the same as graph displayed the first time you open the test to review.

It is impossible to make the graph work both ways, there are too many options that be set. In order to make sure RadiMation always displays the correct graph you can set the lines correct in the graph configuration.


Information.png
Note: It is still possible to access the export window of the graph module itself. Click the graph with the left mouse button and press the 'x' on the keyboard
Information.png
Note: Customization of the graphs is only possible in Multiband tests
Information.png
This functionality is available in RadiMation® version 5.1 and newer.