Line 23: Line 23:
 
** radstdcl: run time error 339. component MSCOMCTL.ocx or one of its dependencies not correctly registered: a file is missing
 
** radstdcl: run time error 339. component MSCOMCTL.ocx or one of its dependencies not correctly registered: a file is missing
 
# The ocx is not available in the system32 dir.
 
# The ocx is not available in the system32 dir.
 +
Information:
 +
http://msdn.microsoft.com/en-us/vbrun/ms788708.aspx
  
 +
'''what does not work:'''
 +
 +
* install the libs from here: http://www.microsoft.com/downloads/details.aspx?familyid=25437D98-51D0-41C1-BB14-64662F5F62FE&displaylang=en
 +
 +
'''what works:'''
 +
* copy the MSCOMCTL.ocx and the comdlg32 to the system32 folder and under admin run regsvr32.
  
 
== List of items that need to be investigated ==
 
== List of items that need to be investigated ==
 
* is the last sentinal software driver used?
 
* is the last sentinal software driver used?

Revision as of 15:23, 8 December 2009

Is RadiMation on Microsoft Windows® 7® supported?

Currently RadiMation is NOT yet officially supporting the Microsoft Windows 7® operating system.

The reason this that some libraries used by RadiMation® are not supported in Windows 7.

Goal of this document

This page is created to document the know problems with running RadiMation® on Windows 7 and give solutions where possible.

Versions used

To investigate the Windows 7 professional 32 bits was used in combination with RadiMation® 5.6.8.

Installation

Radimation is installed with admin rights, by rights click and then run with administrator rights. Installation did not fire any items.

Issues

  • Running RadiMation® from the desktop icon is just giving the message "unexpected error; quitting"
  • Running Radimat-main, gives: unexpected error; quitting
  • running Radimat.exe under admin account, RadiMation® is not running.
  • running Radimat-main.exe under admin account:
    • Darestd2: automation error '440'
    • radstdcl: run time error 339. component MSCOMCTL.ocx or one of its dependencies not correctly registered: a file is missing
  1. The ocx is not available in the system32 dir.

Information: http://msdn.microsoft.com/en-us/vbrun/ms788708.aspx

what does not work:

what works:

  • copy the MSCOMCTL.ocx and the comdlg32 to the system32 folder and under admin run regsvr32.

List of items that need to be investigated

  • is the last sentinal software driver used?