Difference between revisions of "RadiMationInterface.can"

From RadiWiki
Jump to: navigation, search
(Explanation of available events/functions)
Line 19: Line 19:
 
'''Unit parameter:''' dBm
 
'''Unit parameter:''' dBm
 
==Test_Forward_Power==
 
==Test_Forward_Power==
 +
The measured value of the forward power.
 +
 +
'''Parameter:''' mdPowerIndBm
 +
 +
'''Unit parameter:''' dBm
 
==Test_Reflected_Power==
 
==Test_Reflected_Power==
 +
The measured value of the reflected power.
 +
 +
'''Parameter:''' mdPowerIndBm
 +
 +
'''Unit parameter:''' dBm
 
==Test_Average_Field==
 
==Test_Average_Field==
 +
The measured value of the average field.
 +
 +
'''Parameter:''' mdFieldVm
 +
 +
'''Unit parameter:''' V/m
 
==Test_Calculated_Field==
 
==Test_Calculated_Field==
 +
The calculated value of the field based on the calibration file.
 +
 +
'''Parameter:''' mdFieldVm
 +
 +
'''Unit parameter:''' V/m
 
==Test_Measured_Current==
 
==Test_Measured_Current==
 
==Test_Sensor_Power==
 
==Test_Sensor_Power==

Revision as of 08:53, 28 October 2010

The RadiMationInterface.can is an interface between the RadiMation software and CANoe and CANalyser.

By inserting this file inside your CANoe/CANalyser project you are able to extract information from RadiMation using CANoe/CANalyser.

You can download the file here

Explanation of available events/functions

Test_Frequency

The current frequency of the test, in other words the frequency of the signal generator.

Parameter: mdFreqMHz

Unit parameter: MHz

Test_Carrier_Level

The carrier level of the signal generator

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Forward_Power

The measured value of the forward power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Reflected_Power

The measured value of the reflected power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Average_Field

The measured value of the average field.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Calculated_Field

The calculated value of the field based on the calibration file.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Measured_Current

Test_Sensor_Power

Test_Amplitude_Modulation_Internal

Test_Amplitude_Modulation_External

Test_Frequency_Modulation_Internal

Test_Frequency_Modulation_External

Test_Pulse_Modulation_Internal

Test_Pulse_Modulation_External

Test_Modulation_On

Test_Modulation_Off

Antenna_Movement_Started

Antenna_Movement_Stopped

Antenna_Movement_Percentage

Antenna_Movement_Changing_Polarisation

TurnTable_Movement_Started

TurnTable_Movement_Stopped

TurnTable_Movement_Turning_Percentage