Difference between revisions of "RadiMationInterface.can"

From RadiWiki
Jump to: navigation, search
(Explanation of available events/functions)
(Explanation of available events/functions)
Line 51: Line 51:
 
==Test_Pulse_Modulation_External==
 
==Test_Pulse_Modulation_External==
 
==Test_Modulation_On==
 
==Test_Modulation_On==
 +
The currently configured modulation is turned on.
 
==Test_Modulation_Off==
 
==Test_Modulation_Off==
 +
The modulation is turned off.
 
==Antenna_Movement_Started==
 
==Antenna_Movement_Started==
 
Starting of the movement of the antenna tower with the target position of the antenna tower.
 
Starting of the movement of the antenna tower with the target position of the antenna tower.
Line 71: Line 73:
 
'''Unit parameter:''' %
 
'''Unit parameter:''' %
 
==Antenna_Movement_Changing_Polarisation==
 
==Antenna_Movement_Changing_Polarisation==
 +
Changing the antenna polarisation.
 +
 +
'''Parameter:''' target
 +
 +
'''Unit parameter:''' unitless
 +
 +
When the target is 1 the antenna is changed to horizontal.
 +
 +
When the target is 2 the antenna is changed to vertical.
 
==TurnTable_Movement_Started==
 
==TurnTable_Movement_Started==
 
Starting of the movement of the turn table with the target position of the turn table.
 
Starting of the movement of the turn table with the target position of the turn table.

Revision as of 09:24, 28 October 2010

The RadiMationInterface.can is an interface between the RadiMation software and CANoe and CANalyser.

By inserting this file inside your CANoe/CANalyser project you are able to extract information from RadiMation using CANoe/CANalyser.

You can download the file here

Explanation of available events/functions

Test_Frequency

The current frequency of the test, in other words the frequency of the signal generator.

Parameter: mdFreqMHz

Unit parameter: MHz

Test_Carrier_Level

The carrier level of the signal generator

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Forward_Power

The measured value of the forward power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Reflected_Power

The measured value of the reflected power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Average_Field

The measured value of the average field.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Calculated_Field

The calculated value of the field based on the calibration file.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Measured_Current

Test_Sensor_Power

Test_Amplitude_Modulation_Internal

Test_Amplitude_Modulation_External

Test_Frequency_Modulation_Internal

Test_Frequency_Modulation_External

Test_Pulse_Modulation_Internal

Test_Pulse_Modulation_External

Test_Modulation_On

The currently configured modulation is turned on.

Test_Modulation_Off

The modulation is turned off.

Antenna_Movement_Started

Starting of the movement of the antenna tower with the target position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Stopped

The stop position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Percentage

The current percentage of the antenna tower movement from the start position to the end position

Parameter: percentage

Unit parameter: %

Antenna_Movement_Changing_Polarisation

Changing the antenna polarisation.

Parameter: target

Unit parameter: unitless

When the target is 1 the antenna is changed to horizontal.

When the target is 2 the antenna is changed to vertical.

TurnTable_Movement_Started

Starting of the movement of the turn table with the target position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Stopped

The stop position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Turning_Percentage

The current percentage of the turn table movement from the start position to the end position

Parameter: percentage

Unit parameter: %